Vermont Casting PDV20: 3920, SDVR manual Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater

Page 1

INSTALLER / CONSUMER SAFETY INFORMATION

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE.

WARNING!

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP- ERTY DAMAGE, PERSONAL IN- JURY OR LOSS OF LIFE.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This appliance may be installed in an after market permanently located manufactured (mobile) home where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate.

This appliance is not convertible for use with other gases unless a certified kit is used.

Pinnacle & Stardance

Direct Vent, Rear Vent

Gas Heater

Models SDVR, PDV20: 3920, 3926,

3930, 3936, 3960, 3966, 3970,

3976,

4065, 4070, 4075, 4080

Homeowner’s Installation

and Operating Manual

E

S

 

IG

N

D

 

CERTIFIED

C

D

E

 

RTIFIE

CFM Specialty Home Products

410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777

www.majesticproducts.com • www.vermontcastings.com

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

20007066 12/04 Rev. 3

Image 1
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Stardance Direct Vent Gas Heater Stove Dimensions Pinnacle Direct Vent Gas HeaterMinimum Clearances to Combustible Materials Clearance RequirementsMantel Clearances Hearth Requirements Gas SpecificationsGas Inlet and Manifold Pressures Input Model Fuel Gas Control BTU/hHorizontal Termination High ElevationsVent Termination Clearances Vertical TerminationLocation of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Vent Components Install Optional Fan Kit #2960/FK28 InstallationFan Kit Contents Unpack the StoveFor U.S. installations The venting system must Venting System Assembly Direct VentFor Canadian installations The venting system must General InformationThrough Side Wall Vent Termination Below Grade PDV20 with Rear Vent Kit 7TFSRSK installationInstall inner starter pipe and inner elbow Side Wall Termination AssemblyDetermine the vertical pipe length ³⁄₈ x 9³⁄₈ 240 x 240mm Vertical Through the Roof Vent AssemblyFireplace Vent Termination Clearances Vertical Through Existing ChimneyFireplace Vent System Fireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Install ON/OFF Switch R Models only Complete the AssemblyConnect the Gas Supply Line Burner InformationThis completes assembly of the PDV20 and Sdvr stove Install the Front PlateThermostat Connection Use only a thermostat rated for 500 750 millivoltsLogs Install the Log SetFlame Characteristics Flame & Temperature AdjustmentOperation Your First FireCorrect pilot flame pattern. PSE Pilot To Turn Off Gas To Heater Lighting And Operating InstructionsWhat to do if YOU Smell GAS Symptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Conversion Procedure Conversion PrecautionsAuto Path Fuel Conversion InstructionsPilot Type Models 3920, 3930, 4065, 4070 R Models OnlyAll Models Models 3960, 3970, 4075, 4080 RF Models OnlyConversion to Natural Gas Input BTU/h Conversion to LP Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly Wiring Diagrams Stove DisassemblyPinnacle PDV20 / Stardance Sdvr Direct Vent/Rear Vent PDV20 Sdvr DescriptionFuel Conversion Kits Remote Controls Optional AccessoriesFan Kits Screen KitIf Warranty Service is NEEDED… Product Covered by this WarrantyCFM Specialty Home Products

3966, 4080, 3926, 3936, 3960 specifications

Vermont Casting is renowned for its craftsmanship and quality in the hearth industry, particularly with its range of wood and gas stoves. Among its standout models are the 4065, 4075, 4070, 3976, and 3970. Each of these models presents unique features and advanced technologies that cater to a variety of heating needs and preferences.

The Vermont Casting 4065 model is designed with efficiency and usability in mind. Its advanced air management system allows for precise control over combustion, ensuring that homeowners enjoy a longer burn time while minimizing emissions. The large glass door provides an excellent view of the fire, making it a centerpiece in any room. Additionally, the 4065 is built from heavy-duty cast iron, which not only enhances durability but also retains heat longer.

Moving on to the 4075 model, this stove offers an impressive heat output, making it suitable for larger spaces. The 4075 incorporates a unique catalytic combustor, which boosts efficiency by enabling cleaner burns and reducing smoke output. This model also features a user-friendly ash removal system, simplifying maintenance and enhancing user experience.

The 4070 model stands out with its modern design and customizable options. It comes in various colors and finishes, allowing homeowners to tailor it to their interior design style. Like the other models, it emphasizes efficiency with a built-in heat exchanger, maximizing heat transfer to the surrounding space and ensuring optimal comfort.

The Vermont Casting 3976 is a powerhouse of innovation. Equipped with Vermont Casting’s signature cast iron construction, it provides exceptional heat retention and distribution. It features a powerful blower option that can be added for enhanced heat circulation, making it ideal for larger homes or open floor plans. The 3976 also boasts an easy-to-use control panel that allows for intuitive operation.

Finally, the 3970 model is a versatile choice for those seeking a balance of size and efficiency. It offers a compact design without sacrificing performance, making it ideal for smaller rooms. The 3970 includes the same advanced air control system found in larger models, ensuring efficient combustion and heat output.

In summary, Vermont Casting’s 4065, 4075, 4070, 3976, and 3970 models exemplify the perfect blend of traditional craftsmanship and modern technology. With exceptional features such as catalytic combustors, advanced air management, and customizable designs, these stoves offer both aesthetic appeal and functional efficiency, meeting a range of heating needs for contemporary homeowners.