Vermont Casting 4075, SDVR, PDV20: 3920, 3930, 4070, 3976, 4065, 3970, 3960, 3936, 3926 Table of Contents

Page 2

Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Table of Contents

PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.

Thank you and congratulations on your purchase of a Vermont Castings stove.

IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.

Installation & Operating Instructions

 

Stove Dimensions

4

Clearance Requirements

5

Minimum Clearances, Parallel Installation, Corner Installation

5

Minimum Clearances, Alcove Installation

6

Mantel Clearances

6

Hearth Requirements

6

Gas Specifications

6

Gas Inlet and Manifold Pressures

6

High Elevations

7

Horizontal Termination

7

Vertical Termination

8

Vent Termination Clearances

8

General Venting Information - Termination Location

10

Termination Clearances

11

Vent Components

12

Installation

 

Install Optional FK28 Fan Kit

13

Venting System Assembly - Direct Vent

14

Rear Vent

14

Through Side Wall / Vent Termination Below Grade

15

Side Wall Termination Assembly

16

Vent Termination Below Grade

17

Vertical (Through the Roof) Vent Assembly

18

Vertical Through Existing Chimney

19

Fireplace Vent Termination Clearances

19

Fireplace Installation Requirements

21

Connect Gas Supply Line

23

Burner Information

23

Complete the Assembly

23

Install ON/OFF Switch (R Models Only)

23

Install the Front Plate

24

Thermostat Connection

24

Install the Log Set

25

Operation

 

Operable Doors

26

Your First Fire

26

Pilot and Burner Inspection

26

Flame & Temperature Adjustment

26

Flame Characteristics

26

Lighting and Operating Instructions

28

Troubleshooting

29

Instructions for RF Comfort Control Valve

30

Fuel Conversion Instructions

33

Maintenance

 

Annual System Inspection

36

Logset and Burner Cleaning

36

Care of Cast Iron

36

Cleaning the Glass

36

Glass Replacement

36

Gasket Replacement

37

Inspect the Vent System Annually

37

Check the Gas Flame Regularly

37

Stove Disassembly

38

Wiring Diagrams

38

Replacement Parts

39

Optional Accessories

42

Warranty

43

2

20007066

Image 2
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Pinnacle Direct Vent Gas Heater Stove Dimensions Stardance Direct Vent Gas HeaterClearance Requirements Minimum Clearances to Combustible MaterialsGas Inlet and Manifold Pressures Gas SpecificationsMantel Clearances Hearth Requirements Input Model Fuel Gas Control BTU/hHigh Elevations Horizontal TerminationVertical Termination Vent Termination ClearancesLocation of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances Vent Components Fan Kit Contents InstallationInstall Optional Fan Kit #2960/FK28 Unpack the StoveFor Canadian installations The venting system must Venting System Assembly Direct VentFor U.S. installations The venting system must General InformationPDV20 with Rear Vent Kit 7TFSRSK installation Through Side Wall Vent Termination Below GradeSide Wall Termination Assembly Install inner starter pipe and inner elbowDetermine the vertical pipe length Vertical Through the Roof Vent Assembly ³⁄₈ x 9³⁄₈ 240 x 240mmVertical Through Existing Chimney Fireplace Vent Termination ClearancesFireplace Vent System Fireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Connect the Gas Supply Line Complete the AssemblyInstall ON/OFF Switch R Models only Burner InformationThermostat Connection Install the Front PlateThis completes assembly of the PDV20 and Sdvr stove Use only a thermostat rated for 500 750 millivoltsInstall the Log Set LogsOperation Flame & Temperature AdjustmentFlame Characteristics Your First FireCorrect pilot flame pattern. PSE Pilot What to do if YOU Smell GAS Lighting And Operating InstructionsTo Turn Off Gas To Heater Troubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path Auto Path Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsModels 3920, 3930, 4065, 4070 R Models Only Pilot TypeConversion to Natural Gas Input BTU/h Models 3960, 3970, 4075, 4080 RF Models OnlyAll Models Conversion to LP Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Stove Disassembly Wiring DiagramsPinnacle PDV20 / Stardance Sdvr Direct Vent/Rear Vent Description PDV20 SdvrFuel Conversion Kits Fan Kits Optional AccessoriesRemote Controls Screen KitProduct Covered by this Warranty If Warranty Service is NEEDED…CFM Specialty Home Products

3966, 4080, 3926, 3936, 3960 specifications

Vermont Casting is renowned for its craftsmanship and quality in the hearth industry, particularly with its range of wood and gas stoves. Among its standout models are the 4065, 4075, 4070, 3976, and 3970. Each of these models presents unique features and advanced technologies that cater to a variety of heating needs and preferences.

The Vermont Casting 4065 model is designed with efficiency and usability in mind. Its advanced air management system allows for precise control over combustion, ensuring that homeowners enjoy a longer burn time while minimizing emissions. The large glass door provides an excellent view of the fire, making it a centerpiece in any room. Additionally, the 4065 is built from heavy-duty cast iron, which not only enhances durability but also retains heat longer.

Moving on to the 4075 model, this stove offers an impressive heat output, making it suitable for larger spaces. The 4075 incorporates a unique catalytic combustor, which boosts efficiency by enabling cleaner burns and reducing smoke output. This model also features a user-friendly ash removal system, simplifying maintenance and enhancing user experience.

The 4070 model stands out with its modern design and customizable options. It comes in various colors and finishes, allowing homeowners to tailor it to their interior design style. Like the other models, it emphasizes efficiency with a built-in heat exchanger, maximizing heat transfer to the surrounding space and ensuring optimal comfort.

The Vermont Casting 3976 is a powerhouse of innovation. Equipped with Vermont Casting’s signature cast iron construction, it provides exceptional heat retention and distribution. It features a powerful blower option that can be added for enhanced heat circulation, making it ideal for larger homes or open floor plans. The 3976 also boasts an easy-to-use control panel that allows for intuitive operation.

Finally, the 3970 model is a versatile choice for those seeking a balance of size and efficiency. It offers a compact design without sacrificing performance, making it ideal for smaller rooms. The 3970 includes the same advanced air control system found in larger models, ensuring efficient combustion and heat output.

In summary, Vermont Casting’s 4065, 4075, 4070, 3976, and 3970 models exemplify the perfect blend of traditional craftsmanship and modern technology. With exceptional features such as catalytic combustors, advanced air management, and customizable designs, these stoves offer both aesthetic appeal and functional efficiency, meeting a range of heating needs for contemporary homeowners.