Check the rating plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The PDV20 and SDVR may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on Page 41.

CAUTION

This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below.

The PDV20 and SDVR Heaters and the individual shutoff valves must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The PDV20 and SDVR Heaters must be isolated from the gas supply piping system by closing the individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.

There must be a gas shutoff between the stove and the supply.

In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 21,000 BTUs at a manifold pressure of 3.5” and mini- mum inlet supply for adjustment of 5.5” w.c.

In order to connect Propane, use a fitting with 3/ 8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 21,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjustment of 11.0” w.c.

In the U.S.: Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority.

In Canada: consult the local authority and CSA-B149.1 installation code.

Connect the gas supply and test for leaks. Use a mild soap and water solution applied with a brush no larger than 1” (25mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

Burner Information

The appliance must only use the gas specified on the rating plate, unless converted using a Vermont Castings Fuel Conversion Kit. Refer to Page 41 for correct Fuel Conversion Kit for your stove model.

Coversion instructions are provided with each kit and beginning on Page 33 of this manual.

THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES.

THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY.

In order to connect Natural Gas, use a fitting with a 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 21,000 BTU’s at a manifold pressure of 3.5” and minimum inlet supply for adjustment of 5.5” w.c.

In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 21,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjustment of 11.0” w.c.

Complete the Assembly

Open the swiveling latches (cams) on the top left and right corners of the glass frame.

Position the glass and frame against the firebox by placing the bottom edge on the brackets on the bottom face of the firebox.

Swing the assembly against the firebox, and close the latches firmly against the pins protruding from the firebox top.

Install ON/OFF Switch (R Models ONLY)

The switch assembly parts are found in the parts bag.

1.Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 40)

2.Run wires down back of stove, under bottom of rear shroud to valve.

3.Attach wires to valve terminals. (Fig. 41)

20007066

23

Image 23
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Stardance Direct Vent Gas Heater Stove Dimensions Pinnacle Direct Vent Gas HeaterMinimum Clearances to Combustible Materials Clearance RequirementsInput Model Fuel Gas Control BTU/h Gas SpecificationsMantel Clearances Hearth Requirements Gas Inlet and Manifold PressuresHorizontal Termination High ElevationsVent Termination Clearances Vertical TerminationLocation of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Vent Components Unpack the Stove InstallationInstall Optional Fan Kit #2960/FK28 Fan Kit ContentsGeneral Information Venting System Assembly Direct VentFor U.S. installations The venting system must For Canadian installations The venting system mustThrough Side Wall Vent Termination Below Grade PDV20 with Rear Vent Kit 7TFSRSK installationInstall inner starter pipe and inner elbow Side Wall Termination AssemblyDetermine the vertical pipe length ³⁄₈ x 9³⁄₈ 240 x 240mm Vertical Through the Roof Vent AssemblyFireplace Vent Termination Clearances Vertical Through Existing ChimneyFireplace Vent System Fireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Burner Information Complete the AssemblyInstall ON/OFF Switch R Models only Connect the Gas Supply LineUse only a thermostat rated for 500 750 millivolts Install the Front PlateThis completes assembly of the PDV20 and Sdvr stove Thermostat ConnectionLogs Install the Log SetYour First Fire Flame & Temperature AdjustmentFlame Characteristics OperationCorrect pilot flame pattern. PSE Pilot What to do if YOU Smell GAS Lighting And Operating InstructionsTo Turn Off Gas To Heater Symptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLocal Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Auto PathPilot Type Models 3920, 3930, 4065, 4070 R Models OnlyConversion to LP Input BTU/h Models 3960, 3970, 4075, 4080 RF Models OnlyAll Models Conversion to Natural Gas Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Wiring Diagrams Stove DisassemblyPinnacle PDV20 / Stardance Sdvr Direct Vent/Rear Vent PDV20 Sdvr DescriptionFuel Conversion Kits Screen Kit Optional AccessoriesRemote Controls Fan KitsIf Warranty Service is NEEDED… Product Covered by this WarrantyCFM Specialty Home Products

3966, 4080, 3926, 3936, 3960 specifications

Vermont Casting is renowned for its craftsmanship and quality in the hearth industry, particularly with its range of wood and gas stoves. Among its standout models are the 4065, 4075, 4070, 3976, and 3970. Each of these models presents unique features and advanced technologies that cater to a variety of heating needs and preferences.

The Vermont Casting 4065 model is designed with efficiency and usability in mind. Its advanced air management system allows for precise control over combustion, ensuring that homeowners enjoy a longer burn time while minimizing emissions. The large glass door provides an excellent view of the fire, making it a centerpiece in any room. Additionally, the 4065 is built from heavy-duty cast iron, which not only enhances durability but also retains heat longer.

Moving on to the 4075 model, this stove offers an impressive heat output, making it suitable for larger spaces. The 4075 incorporates a unique catalytic combustor, which boosts efficiency by enabling cleaner burns and reducing smoke output. This model also features a user-friendly ash removal system, simplifying maintenance and enhancing user experience.

The 4070 model stands out with its modern design and customizable options. It comes in various colors and finishes, allowing homeowners to tailor it to their interior design style. Like the other models, it emphasizes efficiency with a built-in heat exchanger, maximizing heat transfer to the surrounding space and ensuring optimal comfort.

The Vermont Casting 3976 is a powerhouse of innovation. Equipped with Vermont Casting’s signature cast iron construction, it provides exceptional heat retention and distribution. It features a powerful blower option that can be added for enhanced heat circulation, making it ideal for larger homes or open floor plans. The 3976 also boasts an easy-to-use control panel that allows for intuitive operation.

Finally, the 3970 model is a versatile choice for those seeking a balance of size and efficiency. It offers a compact design without sacrificing performance, making it ideal for smaller rooms. The 3970 includes the same advanced air control system found in larger models, ensuring efficient combustion and heat output.

In summary, Vermont Casting’s 4065, 4075, 4070, 3976, and 3970 models exemplify the perfect blend of traditional craftsmanship and modern technology. With exceptional features such as catalytic combustors, advanced air management, and customizable designs, these stoves offer both aesthetic appeal and functional efficiency, meeting a range of heating needs for contemporary homeowners.