Vermont Casting LHER20 manual Installation & Operating Instructions, Insert Applications

Page 3

LHE Series Natural Vent Insert

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S. Installations follow local codes and/or the current National Fuel Gas Code ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts, all gas fittings and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS FIREPLACE PLEASE NOTE THE FOLLOWING:

1.This appliance gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing.

3.Children should be carefully supervised when they are in the same room as your appliance.

4.Under no circumstances should this appliance be modified. Parts removed for servicing should be replaced prior to operating this appliance again.

5.Installation and any repairs to this appliance should be car- ried out by a qualified service person. A professional service person should be contacted to inspect this appliance an- nually. Make it a practice to have all of your gas appliances checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this ap- pliance should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit.

7.The venting system (chimney) of this appliance should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapor and liquids. This appliance should not be used as a drying rack for cloth- ing, nor should Christmas stockings or decorations be hung in the area of it.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this appliance.

10.Whether the zero clearance kit is installed directly on carpet- ing, vinyl tile or any combustible material other than wood, this heater must be installed on a metal or wood panel extending the full width and depth of the heater. The insert can not be installed directly onto or into combustibles.

This appliance may be installed in an aftermarket per- manently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indi- cated on the rating plate.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer before installing a television or other electronic de- vice above this fireplace.

IMPORTANT:

PLEASE READ THE FOLLOWING CAREFULLY

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open

all windows.

It is recommended that you burn your fireplace for at least ten

(10)hours the first time you use it. If optional fan kit has been installed, place fan in the "OFF" position during this time.

Locating Your Gas Fireplace Insert

with Zero Clearance Kit

X EAB

C

X D

X F

FP1249a

Fig. 1 Locating unit with zero clearance kit.

A)

Flat on wall

B)

Cross corner

C)

Island

D)

*Room divider

E)

*Flat on wall corner

F)

Chase installation

NOTE: (Fig. 1)

*When you install your fireplace in (D) Room divider or (E) Flat on wall corner positions, a minimum of 6 (X) inches (153mm) clearance must be maintained from the perpendicular wall and the outer edge of the trim.

Insert Applications

Before installing the gas fireplace insert, consideration must be given to the functioning needs of the fireplace. The size of the fireplace cavity (min. 25¹⁄"W x 17¹⁄"H x 13¹⁄" D (641 x 438 x 343 mm) for the LHEC20 and LHER20, 28³⁄"W x 21"H x 15¹⁄"D (730 x 533 x 394 mm) for LHEC30 and LHER30), the design of the chimney for effective venting should be determined. The availability of the gas supply as well as electricity for the insert fan must be confirmed.

Your Natural Vent Insert unit is designed to be vented vertically with a minimum height of 12' (4 m) and a maximum vertical height of 35' (11 m).

10005360

3

Image 3
Contents LHEC20 LHER30 LHEC30 Table of Contents Please Read the Following Carefully Installation & Operating InstructionsLocating Your Gas Fireplace Insert With Zero Clearance Kit Insert ApplicationsMinimum Fireplace Insert Opening Fireplace & Trim DimensionsAn alternate air supply is recommended with this component MantelsFraming & Finishing Zero Clearance ApplicationsHigh Elevations Gas Line InstallationGas Specifications Gas Inlet & Manifold PressuresFan Removal Instructions Installation of Trim Switch For RN/RP Gas ValvesGas Supply Pressures Fan KitFor left side installation, reverse switch position Venting InstallationTest Chimney Draw Common Flue InstallationsLiner Installation Draft Relief OpeningBlocked Flue Shut Off System Blocked Flue Shut Off Switch AccessCeramic Refractory Installation Access to the shut off switch from outside of the insertOperating Instructions First Firing Flame Adjustment RN/RP ModelsFlame Characteristics Large Lava Rock PlacementPSE Pilot What to do if YOU Smell GAS To Turn Off Gas To HeaterSymptom Possible Causes Corrective Action Troubleshooting the Gas Control SystemHoneywell Millivolt Valve Instructions for RF Comfort Control Valve Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeChange Between F/C Temperature Units Delay Timer ModeAuto Mode Fan Override During Auto ModeAuto Path LED Count Service Action Replace valveLocal Path Burner and Burner Compartment MaintenanceTrim Cleaning Cleaning the Standing Pilot Control SystemLHE Series LHER20 LHEC20 LHER30 LHEC30 DescriptionRemote Switch for RN or RP Units Optional Accessories Remove the bottom door rail If Warranty Service is NEEDED… Product Covered by this WarrantyAFUE% Efficiency Ratings

LHER20 specifications

The Vermont Casting LHER20 is a premium wood-burning stove that combines efficiency, aesthetics, and environmentally responsible heating. Known for its high-quality construction and innovative technologies, this model is designed to provide optimal warmth while also enhancing any living space with its classic design.

One of the standout features of the LHER20 is its exceptional thermal efficiency. With an EPA-certified design, the stove meets stringent emissions standards, ensuring that it burns wood cleanly and efficiently. This not only helps in reducing environmental impact but also translates to longer burn times and less frequent reloading, providing convenience for users.

The LHER20 incorporates advanced air management systems that promote secondary combustion. This technology re-burns exit gases from the initial burn, maximizing fuel utilization and enhancing heat output. As a result, this stove delivers a remarkable heat output, making it ideal for heating medium to large spaces.

Crafted from high-quality cast iron, the Vermont Casting LHER20 offers both durability and aesthetic appeal. It comes in several attractive finishes, including matte black and classic enamel colors, allowing homeowners to choose a look that complements their decor. The traditional styling features large glass doors that provide a captivating view of the fire, creating a cozy atmosphere and enhancing the overall experience of wood-burning.

Another notable characteristic is its user-friendly operation. The LHER20 features a simple damper control system, allowing users to easily adjust airflow for controlling the burn rate. This ensures a steady and consistent heat output while allowing users to tailor the stove’s performance to their preferences.

In terms of size, the LHER20 is compact yet powerful, making it suitable for various spaces, including cabins, homes, or even larger open-plan areas. The stove's efficient heat delivery helps create a comfortable environment during the cold months, proving its worth as a reliable heating solution.

Overall, the Vermont Casting LHER20 is an exemplary wood stove that combines tradition with modern technology. Its outstanding features, environmental responsibility, and aesthetic appeal make it a sought-after choice for those seeking to embrace the warmth and charm of wood-burning stoves in their homes. Whether for aesthetics, efficiency, or performance, the LHER20 stands as a testament to Vermont Casting's commitment to quality.