TROUBLE SHOOTING
| Issue | Possible Cause | Solution | 
| After Installation, | The power is not on. | Make sure the circuit breaker and the unit’s power is | 
| both motors and | 
 | ON. Use a voltage meter to check the power supply. | 
| lights are not | The wire connection is not secure. | Check and tighten wire connection. | 
| working. | The control panel and processor board | Check wire continuity from control panel to processor | 
| 
 | wiring are disconnected. | board. | 
| 
 | The motor transformer is defective. | Check the power input and power output on the | 
| 
 | 
 | motor transformer. | 
| 
 | 
 | If it’s needed, replace the motor transformer. | 
| 
 | 
 | 
 | 
| 
 | The control panel and processor board is | Replace the control panel or processor board. | 
| 
 | defective. | 
 | 
| Lights are | The motor(s) is defective. | Replace the motor. | 
| working, but | The capacitor(s) is defective. | Replace capacitor(s). | 
| motor(s) is not. | The control panel or processor board is | Replace the control panel or processing board. | 
| 
 | defective. | 
 | 
| The range | The blower system is not secure. | Tighten the turbine impeller/squirrel cage and air | 
| hood is | 
 | chamber. | 
| vibrating. | The turbine impeller/squirrel cage is | Replace the turbine impeller/squirrel cage. | 
| 
 | not balanced. | 
 | 
| 
 | Hood is not secured in place. | Check the installation of hood, tighten the | 
| 
 | 
 | mounting bracket. | 
| The motor is | Halogen Light bulb(s) is defective. | Try placing the trouble light bulb(s) to a working | 
| working, but | 
 | socket, if the bulb(s) still doesn’t work; replace | 
| the lights are | 
 | the halogen light bulb(s). | 
| not working. | The light wiring(s) is loose. | Check wire continuity from processor board to | 
| 
 | 
 | light transformer to halogen light housing(s). | 
| 
 | Light transformer is defective. | Check power input and power output on the light | 
| 
 | 
 | transformer. If it’s needed, replace the light | 
| 
 | 
 | transformer. | 
| 
 | The control panel or processor board is | Replace the control panel or processing board. | 
| 
 | defective. | 
 | 
| 
 | 
 | 
 | 
| The range | The range hood is installed outside of | Adjust the clearance between the range hoods | 
| hood is not | the manufacture recommended | and cook top to 27” to 30”. For Island range | 
| venting out | clearance. | hood, the clearance between the range hoods | 
| correctly. | 
 | and cook top is 30” to 36”. | 
| 
 | There is no  | Open the window to enhance the performance | 
| 
 | house. | of the range hood by creating a sufficient make- | 
| 
 | 
 | up air. | 
| 
 | Obstacle blocking the pipe work. | Remove all obstacles from the duct work. | 
| 
 | 
 | 
 | 
| 
 | The pipe size is smaller than the | Change the ducting according to the | 
| 
 | suggested pipe size. | manufacture suggestion. | 
| Cold air is | The pipe connection is not properly | Check the pipe installation. | 
| coming into the | sealed. | 
 | 
| home. | The damper is not properly installed or | Check the damper installation. | 
| 
 | is missing from the installation. | 
 | 
| 
 | The damper is not installed. | By installing the damper, it will help to eliminate | 
| 
 | 
 | air backflow. | 
28