INSTALLATION Continued
NOTE: When mounting a salamander over an existing range in the field, an independent fussed connection must be made though the knock out plate provided in the main back of the salamander..
Assembly of Backguard/High Shelf
The back guard or high shelf will have been shipped separately.. To install, put the backguard/high self on the rear of the range, slipping the uprights into the opening on each burner box side.. Fasten the upright to the burner box side with four hex fasteners provided..
Code Requirements
The Garland S/SS680 series complies with the standards CSA C22..2 no..109 – latest edition, the UL197 – latest edition and the NSF#4 – latest edition.. The installation and connection of this appliance must comply with current codes.. In Canada
–The Canadian Electrical Code Part 1 and in the USA – The National Electrical Code..
The Garland SU680 series complies with the essential requirements of the Directives 73/23/EEC, 89/336/EEC, 89/392/EEC, 93/68/EEC and the standards, EN60335, IEC801..2, IEC801..3, IEC801..4, IEC801..5, IEC801..6 and IEC801..11..
Electrical Supply
Before attempting the electrical connection, the rating plate should be checked to ensure that the equipment’s electrical characteristics and supply electrical characteristics agree.. On ranges and salamanders the supply entrance is located at the rear or alternatively on the main bottom.. The supply terminal block is accessible from the front.. The electrical supply must be adequate for the voltage, phase, and current marked on the rating plate..
NOTE: A means of disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring..
This equipment is intended to be installed with fixed permanent wiring..
WARNING: This appliance must be grounded..
Single And Three Phase Connection
Unless otherwise noted, all ranges are shipped from the factory for three phase connection.. Salamanders are shipped from the factory for single phase connection.. A wiring diagram is attached to the rear of each appliance.. Visually check all electrical connections.. The range is wired at the factory as specified on the order.. If it is necessary to change the phasing refer to the wiring diagram..
Commissioning
Ensure all circuit breakers located in the lower compartment are set to the ON (1) position
1.Ensure that all controls are in the OFF position and turn on the main electrical supply..
2.Operate each section of the range or salamander in accordance with the instructions given in the Operating Instructions..
3.Check that the product functions correctly and that the voltage supply to the unit does not drop more than 5% when all sections are operated simultaneously..
Page 10 | Part # P153 Rev 1 (02/21/08) |