Installation
The oven must be installed according to the | This oven must be installed by qualified | |||
instructions supplied. |
| personnel to the relevant British Standards. | ||
Technical Data |
| Heating elements rating |
| |
Dimensions of recess |
| Oven element | 1,880 W | |
| Top element | 835 W | ||
Height | 580 mm. | |||
Bottom element | 1,045 W | |||
Width | 560 mm. | |||
|
| |||
Depth | 550 mm. | Convection element | 2,090 W | |
|
| Grill element | 1,795 W | |
Dimensions of the oven cavity |
| Double Grill element | 2,665 W | |
Height | 335 mm. | Pizza Oven Function | 3,135 W | |
Width | 395 mm. | Convection Fan | 30 W | |
Depth | 400 mm. | Oven Light | 15 W | |
Oven capacity | 53 litres | |||
Cooling Fan | 25 W | |||
|
| |||
|
| Total Rating | 3,200 W | |
|
| Supply voltage (50 Hz) |
Electrical Connection
The oven is designed to be connected to
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Live terminal | |||||||
Letter N | - | Neutral terminal | |||||||
|
|
|
|
|
|
| or E | - | Earth terminal |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must comply to the specifications given below.
For Uk use only
Connection | Min. size | Cable / flex | Fuse |
via | Cable/flex | type |
|
|
|
|
|
• Cooker | 2.5 mm2 | PVC/PVC | 20 A |
Control |
| twin and |
|
Circuit |
| earth |
|
|
|
|
|
For Europe use only
Min. size Cable/flex | Cable / flex type | Fuse |
|
|
|
2.5 mm2 | H07 | 15 A |
| H05 |
|
| H05 |
|
| H05 |
|
|
|
|
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperatu- re of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should these safety measures not be carried out.