Installation
The oven must be installed according to the instructions supplied.
This oven must be installed by qualified personnel to the relevant British Standards.
DIMENSIONS | Height |
| 878 mm. |
OF RECESS | Width | ||
| Depth |
| 550 mm. |
|
|
|
|
DIMENSIONS | Height |
| 320 mm. |
OF THE | Width |
| 420 mm. |
MAIN OVEN | Depth |
| 390 mm. |
CAVITY | Oven capacity | 53.2 litres | |
|
|
|
|
DIMENSIONS | Height |
| 185 mm. |
OF THE | Width |
| 420 mm. |
LOWER OVEN | Depth |
| 400 mm. |
CAVITY | Oven capacity | 31 litres | |
|
|
|
|
Upper oven ratings
Oven element | 1.89 kW |
Top element | 0.834 kW |
Bottom element | 1.055 kW |
Convection element | 2.08 kW |
Grill element | 1.82 kW |
Double Grill element | 2.655 kW |
Pizza Oven Function | 3.135 kW |
Bread Proving Function | 1.89 kW |
Convection Fan | 30 W |
Oven Light | 15 W |
Cooling Fan | 25 W |
Total Rating | 3.200 kW |
Lower oven ratings |
|
Oven element | 1.89 kW |
Top element | 0.834 kW |
Grill element | 1.82 kW |
Double Grill element | 2.655 kW |
Oven Light | 15 W |
Total Rating | 2.695 kW |
Total connected load | 5.870 kW |
Electrical Connection
The oven is designed to be connected to
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Live terminal | |||||||
Letter N | - | Neutral terminal | |||||||
|
|
|
|
|
|
| or E | - | Earth terminal |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must comply to the specifications given below.
Connection |
| Min. size |
| Cable / flex |
| Fuse | |
|
|
| |||||
via |
| Cable/flex |
| type |
|
|
|
|
|
|
|
|
|
|
|
For Uk use only |
|
|
|
|
| ||
|
|
|
|
|
|
| |
• Cooker |
| 6 mm2 |
| PVC/PVC |
| 30 A |
|
Control |
|
|
| twin and |
|
|
|
Circuit |
|
|
| earth |
|
|
|
For Europe use only |
|
|
|
|
| ||
|
|
|
|
|
|
| |
|
| 4 mm2 |
| H05 |
| 30 A | |
|
|
|
|
|
|
|
|
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a tempera- ture of more than 60°C above the ambient temperatu- re.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should these safety measures not be carried out.
30