Recirculation
The cooker hood is supplied specified for use in the recirculation mode, with the charcoal filter fitted.
In the recirculation mode contaminated air is passed through the charcoal filter to be purified and recirculated into the kitchen through the grille outlets on either side of the chimney.
Recirculation Connection
Assemble the two halves of the round recirculation extension duct 14.
Push fit the assembled extesion duct 14 on to Ø150mm ducting spigot on top of the motor housing.
Push fit the recirculation spigot 15 onto the other end of the extension duct 14.
Insert the extension ducts item 14.1 into either side of the recirculation spigot 14 ensuring the connections are vertically and horizontally aligned with the outlets in the chimney.
Chimney Stack
The chimney consists of two sections. The lower chimney measures 740mm (with the recirculation grilles on either side) and the upper chimney measures 215mm. The overall installed measurement is min.
Fitting the Chimney
Position the upper chimney section 2.1 and fix the chimney to the upper frame using two Ø2.9x9.5mm screws 12c.
Slide the lower chimney section 2.2 up over the upper chimney and fix the chimny to the lower frame using two Ø2.9x9.5mm screws 12c.
When installed in the recirculation mode the ducting outlet extension pieces 14.1 should align with the rectangular holes in each side of the chimney.
Position the recirculation grilles 8a and 8b so the slats face in a forwards and upwards direction.
Fitting the Hood Body 1
Before fixing the hood body to the frame: Remove the grease filters from the hood body.
Remove the activated charcoal filter.
Using the four M6x10 12f fix the hood body 1 to the frame 7.1b.
15
14.1
14
12c
8b | 8a |
|
12c
12f
14