Faber Island Mount Canopy Rangehood Attach the Support, For Ductless Installations

Page 7
FIGURE 6

ATTACH THE SUPPORT

1. Putathick,protectivecovering over cooktop, set-in range or countertop to protect from damage or dirt.

2. Determine and clearly mark withapencilontheceilingwhere the rangehood will be installed.

.

3. Atemplate(LinFIGURE6)for mountingthesupportissupplied in the carton with the support. Use this template to mark holes for support on the ceiling.

4.Determine and make necessary cuts for the ductwork. The duct opening is shown on the mounting template (L in FIGURE 6). Install ductwork before mounting the support.

IMPORTANT NOTE: BE CAREFUL WHEN DETERMINING THE LOCATION FOR THE HOLE IN YOUR CEILING FOR THE DUCT WORK. THIS HOLE SHOULD NOT BE CENTERED OVER THE CENTER OF THE COOKING SURFACE AS THE DUCT WORK THAT RUNS UP INSIDE THE CHIMNEY AND THROUGH THE CEILING IS NOT IN THE EXACT CENTER OF THE CHIMNEY.

5.Determine the proper location for the Power Supply Cable as indicated on the template. Use a 1 1/4" Drill Bit to make this hole. Run the Power Supply Cable. Use caulking to seal around the hole. DO NOT turn on the power until installation is complete! A knockout is provided at the top of the UPPER CHIMNEYSUPPORT

(E in FIGURE 7).

6.For ducted installations, place the round DAMPER (AinFIGURE 7) into the exhaust opening of the rangehood and press down.

7.Before attaching the support to the ceiling, you must determine the desired length of the support structure and adjust the length of the support by removing the eight screws (indicated in FIGURE 7) with a flat head screwdriver. Once the length of the support is determined, install and tighten the eight screws.

FOR DUCTLESS INSTALLATIONS

Ductlessinstallationsrequirea Ductless Conversion Kit whose components are pictured in FIGURE 8. Do not use the DAMPER (A in FIGURE 7) for ductless installations. The LOWER CHIM- NEYCOVER (B in FIGURE 1) should be discarded and replaced by the new one with the hole from the Ductless Conversion Kit (F in FIGURE 8). The UPPER CHIMNEY COVER (C in FIGURE 1) should be discarded and replaced by the shorter one from the Ductless Conversion Kit (G in FIGURE 8).

FIGURE 8

As indicated in FIGURE 8, place the FLANGE (A) into the exhaust opening of the rangehood and press down. Fit the DUCTLESS DIVERTER EXTENSION VERTICAL (B) over the FLANGE (A) and fit the DUCTLESS DIVERTER (C) over the EXTENSION (B). Fit the DUCTLESS DIVERTER EXTENSION HORIZONTAL (D) into the DIVERTER (C).

MAKE THE ELECTRICAL CONNECTION

Remove the cover from the field wiring compartment. DO NOT turn on the power until installation is complete! Connect the Power Supply Cable to the rangehood. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connector. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector. Connect the Green (Green and Yellow) ground wire under the Green grounding screw.

FIGURE 7

8.Slide the UPPER CHIMNEY COVER (C in FIGURE 1 for ducted installations - the upper chimney that came with the rangehood, or G in FIGURE 8 for ductless installations - the upper chimney that came with the ductless kit) down over the UPPER CHIMNEY SUPPORT (E in FIGURE 7) until it rests on the motor box (D in FIGURE 7). Attach the entire support to the ceiling.

Make sure that the support is firmly attached to the ceiling.

INSTALLING THE RANGEHOOD

1.The UPPER CHIMNEY COVER (C in FIGURE 9) attaches using two screws provided (G in FIGURE 9). Slide up and attach the

UPPER CHIMNEY COVER.

2.Attach the duct work to the DAMPER (A in FIGURE 7). Make sure to seal all joints with duct tape to prevent leaks.

FIGURE 9

3.The LOWER CHIMNEY COVER (B in FIGURE 9) rests on the top of the CANOPY SECTION (A in FIGURE 1) once it is installed. Install the LOWER CHIMNEY COVER by sliding it up over the support.

Forductless installations,line upthe DUCTLESS DIVERTER EXTENSION HORIZONTAL (D in FIGURE 8) with the hole in the LOWER CHIMNEY COVER (F in FIGURE 8) and snap in the VENT GRID (E in FIGURE 8).

Version 3/08 - Page 7

Image 7
Contents Read and Save These Instructions Lisez Bien Cette Fiche Avant Dinstaller LA HotteFor residential use only Venting RequirementsDuctwork Electrical RequirementsUniquement pour usage menager Règlements DévacuationRèglements Dévacuation Additionell Fiche Technique ÉlectriqueCalculate the Ductrun Length Unpack the RangehoodPreparing to Attach the Chimney For Wood Ceilings Use four 4 longVented to the outside Plan the InstallationChimney Cover Not vented to the outsideMake the Electrical Connection For Ductless InstallationsInstalling the Rangehood Attach the SupportMake the Internal Electrical Connections USE and Care Information Wiring DiagramFaber Warranty & Service Save for Your Records De la Figure Installation DU SupportFiltres au Charbon Déballer LA HotteDimensions d’installatioN Avec Conduit Plan DE L’INSTALLATION31 po Dimensions d’installatioN Sans ConduitDe la . Fixer le Installations Sans ConduitInstallation DU Hotte Brancher LE Câble DalimentationConnecter LES Connecteurs Interne AvertissementUtilisation ET Entretien Enregistrez Votre Information Ci-dessous