Faber Island Mount Canopy Rangehood Unpack the Rangehood, Preparing to Attach the Chimney

Page 4

TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

K

I

J

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

PARTS SUPPLIED FOR INSTALLATION

• 1 Hardware Package

• 1 Literature Package

PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork

OPTIONAL ACCESSORIES AVAILABLE

*Ductless Conversion Kit For non-vented installations only

* it is highly recommended that professional style cooking always be vented to the outside

part # 620000042 - Stainless

Replacement Charcoal Filter For non-vented installations only, replace charcoal filter as needed part # 620000041

H

L

M

RANGEHOOD COMPONENTS

A. CANOPY SECTION

B. LOWER CHIMNEY COVER

C. UPPER CHIMNEY COVER

D. LOWER CHIMNEY SUPPORT

E. UPPER CHIMNEY SUPPORT

F. CANOPY SCREWS (short screws)

G. DO NOT USE (long screws)

H. WOOD SHELF BOLTS (long bolts)

I. WOOD SHELF WASHERS

J. WOOD SHELF NUTS

K. MOUNTING TEMPLATE

L. DUCT CLAMPS

M. DAMPER

FIGURE 1

UNPACK THE RANGEHOOD

Remove the rangehood from the carton and place on a flat surface for assembly. Before discarding the packaging, check to make sure that no mounting hardware or parts are missing. DO NOT REMOVE THE PLASTIC COVERING ON THE CHIMNEYS AT THIS TIME! This plastic covering protects the chimney from scratches during installation.

For safe packaging, the entire chimney section of the hood is shipped assembled. It must be disassembled completely for installation. Disassemble packaged chimney components by sliding apart the chimney covers (B and C in FIGURE 1). Remove the UPPER CHIMNEY COVER (C) from the UPPER CHIMNEY SUPPORT (E) by removing the 2 philips screws on the outside top of the chimney cover.

PREPARING TO ATTACH THE CHIMNEY

The rangehood attaches to the ceiling by a metal support structure (D and E in FIGURE 1). This support must be attached to the ceiling before the canopy is attached. This structure must be firmly attached to the ceiling.

FOR WOOD CEILINGS: Use four 4" long

CALCULATE THE DUCTRUN LENGTH

 

 

The ductrun should not exceed 35 equivalent

 

 

45˚ Elbow

3.0 feet

feet if ducted with the required minimum of 6"

roundduct.Calculatethelengthoftheductwork

90˚ Elbow

5.0 feet

by adding the equivalent feet in FIGURE 2 for

90˚ Flat Elbow

12.0 feet

each piece of duct in the system. An example

Wall Cap

0.0 feet

is given in FIGURE 3.

FIGURE 2

 

wood screws and washers.

FORPLASTERORSHEETROCKCEILINGS: If possible, the support must be attached to the ceiling joists. If not, a supporting structure behind the sheet rock must be built.

FOR WOOD SHELVES: Use items H, I, & J in FIGURE 1.

For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as possible.

9

Feet Straight Duct

9.0 feet

2

- 90˚ Elbows

10.0 feet

Wall Cap

0.0 feet

Total System

19.0 feet

FIGURE 3

Version 3/08 - Page 4

Image 4
Contents Lisez Bien Cette Fiche Avant Dinstaller LA Hotte Read and Save These InstructionsVenting Requirements DuctworkElectrical Requirements For residential use onlyRèglements Dévacuation Règlements Dévacuation AdditionellFiche Technique Électrique Uniquement pour usage menagerUnpack the Rangehood Preparing to Attach the ChimneyFor Wood Ceilings Use four 4 long Calculate the Ductrun LengthPlan the Installation Vented to the outsideNot vented to the outside Chimney CoverFor Ductless Installations Installing the RangehoodAttach the Support Make the Electrical ConnectionMake the Internal Electrical Connections Wiring Diagram USE and Care InformationFaber Warranty & Service Save for Your Records Installation DU Support Filtres au CharbonDéballer LA Hotte De la FigurePlan DE L’INSTALLATION Dimensions d’installatioN Avec ConduitDimensions d’installatioN Sans Conduit 31 poInstallations Sans Conduit Installation DU HotteBrancher LE Câble Dalimentation De la . Fixer leAvertissement Connecter LES Connecteurs InterneUtilisation ET Entretien Enregistrez Votre Information Ci-dessous