R
PORTABLE GASOLINE GENERATORS
BATTERY
(Models MGH5000DIE,
MGH7000D, MGH7000DI, and
MGH10000A)
WARNING: Battery gives off explosive gases. Keep sparks, flames, and cigarettes away. Do not remove or install battery cables when engine is cranking or running. Only service or use battery in a
WARNING: Battery contains sulfuric acid. Contact with skin or eyes may cause severe burns. Do not tilt generator with battery installed. Tilting could cause bat- tery acid to spill. Wear protective clothing and face shield when servicing. Keep out of children’s reach.
•If battery acid gets on your skin, wash with water.
•If battery acid gets in your eyes, flush with water at least 15 minutes. Call a doctor at once. Battery acid is poisonous.
•If swallowed, drink large amounts of water or milk. Fol- low with milk of magnesia or vegetable oil. Call a doctor at once.
CAUTION: If you remove bat- tery, insulate the red, positive (+) battery cable terminal. Insulate with electrical tape. Exposed ter- minal may spark when generator runs.
IMPORTANT: Make sure battery connec- tions are the correct polarity. Electric start generators use negative ground,
Always wear safety glasses when working with battery. Make sure battery terminals are clean. Make sure cable connections are tight.
Always shut down engine before removing or attaching battery cables. Always remove the negative
INSTALLING BATTERY CABLES TO ENGINE
1.Attach the red, positive (+) battery cable to the starter solenoid on engine (see Figure 8). The starter solenoid is located directly above the starter on Model MGH10000A. This cable is fac- tory installed.
CAUTION: Do not over tighten positive terminal on starter sole- noid. Positive terminal could ro- tate and cut into negative termi- nal, causing a short.
2.Attach the black, negative
Starter
Solenoid
Red, Positive (+)
Battery Cable
Black,
Negative
Battery Cable
Figure 9 - Connecting Black, Negative
MOUNTING BATTERY TO GENERATOR
1.Secure battery to generator by battery
Note: Model MGH10000A battery is located on opposite side as shown (see Figure 11, page 9).
2.Locate the red, positive (+) battery cable from starter solenoid. Connect it to the positive (+) battery terminal (see Figures 12 and 13, page 9).
3.Locate the black, negative
4.Check battery before starting engine. Make sure fluid levels are full. Make sure battery is charged.
See engine owner’s manual for more information.
Battery
Mounting
Bracket
Nut
starting system.
Models MGH5000DIE, MGH7000D, MGH7000DI, and MGH10000A have an electric starter. A battery is not supplied with generator. You must provide a
Figure 8 - Connecting Red, Positive (+) |
|
|
Battery Cable to Engine Starter Solenoid | 120 | 240V |
| ONLY |
|
(Model MGH7000D Shown) |
| 120 |
ENM | Battery | |
| 00000005 |
|
Hook
Bolt
Figure 10 - Battery
(Model MGH7000D Shown)
8 | 105202 |