Master Lock MGH4000CI, MGH5000CI, MGH5000CIE, MGH6000CI, MGH7000CI Generator Features

Models: HWI3000, MGH3000, MGH4000D, MGH4000DI, MGH5000D, MGH5000DI, MGH5000DIE, MGH6000D, MGH6000DI, MGH7000D, MGH7000DI, MGH10000A MGH4000CI, MGH5000CI, MGH5000CIE, MGH6000CI, MGH7000CI

1 28
Download 28 pages 15.21 Kb
Page 6
Image 6
GENERATOR

R

PORTABLE GASOLINE GENERATORS

GENERATOR

FEATURES

OIL ALERT SYSTEM

The oil alert system protects the engine from low oil damage. This system automatically shuts down the engine and prevents engine restarting if the oil level falls too low.

Note: When this happens, the engine switch remains in the ON position. The oil alert system is wired into the ON/OFF Switch.

If this system shuts down the engine, the engine will not start until you add oil. Add oil to engine (see Engine Oil, page 7).

Note: Operate generator on a level surface. If not level, the oil may flow away from the oil level sensing device. This will cause the oil alert system to shut down engine.

See engine owner’s manual for more information.

ENGINE SW

ON

OFF

Models HWI3000, MGH3000, MGH4000D,

MGH4000DI, MGH5000D, MGH5000DI,

MGH6000D, and MGH6000DI

HONDA

Models

MGH5000DIE,

ON

OFF START

MGH7000D,

 

MGH7000DI, and

 

MGH10000A

ENGINE SW

 

CIRCUIT

 

BREAKER

Figure 2 - Engine Switch Location

FULL POWER SELECTOR SWITCH

All models except HWI3000, MGH3000,

MGH7000D, MGH7000DI, and MGH10000A have a full power selector switch on the control panel. The switch has two positions: 120 VOLT ONLY, and 120/ 240 VOLT.

120 VOLT ONLY: This position sends full power to the 120V receptacles only. 240V power is not available. Use this position when powering 120V items only.

120/240 VOLT: This position sends full power to the 120/240V receptacle. It also powers the 120V receptacles at reduced wattage capacity.

 

Full Power

120 V

120/

ONLY

240V

 

Selector

120 VOLT ONLY Position

 

Full Power

120 V

120/

ONLY

240V

 

Selector

120/240 VOLT Position

Figure 3 - Full Power Selector Switch

IMPORTANT: Do not move the full power selector switch while powering electrical items. Unplug all items before moving switch. Failure to do so can damage switch. Models HWI3000, MGH3000, MGH7000D, MGH7000DI, and MGH10000A do not have this switch. These models provide full power to all receptacles.

ELECTRIC START

(Models MGH5000DIE,

MGH7000D, MGH7000DI, and

MGH10000A)

Models MGH5000DIE, MGH7000D, MGH7000DI, and MGH10000A have elec- tric starters. A battery is not supplied with generator. You must provide a 12-volt, 32- amp-hour battery. For more battery infor- mation, see Battery, page 8.

GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE

All models (Except HWI3000) have a 120- volt ground fault circuit interrupter (GFCI) receptacle. The GFCI receptacle is on the control panel or top cover of alternator (model MGH3000 only). The GFCI pro- tects you against hazardous electrical shock caused when your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is ‘live’ through faulty mechanism, damp or worn insula- tion, etc.

When protected by the GFCI, you may still feel a shock, but the GFCI should cut it off quickly. A person in normal health should not receive serious injury. Note: Infants and very small children may still be affected.

Test Procedure

Check the GFCI receptacle every month. This insures it is working right.

1.Push black TEST button. Red RESET button should pop out. This should trip GFCI, resulting in no electrical power at receptacle. Verify this by plugging test lamp with good bulb into recep- tacle. If lamp does not work, GFCI re- ceptacle is good.

OIL ALERT SYSTEM WARNING: If RESET button does not pop out, do not use the GFCI receptacle. Contact a quali- fied electrician for repairs.

2.If the GFCI receptacle tests okay, re- store power by pushing the RESET button back in. The test lamp should work at this time. IMPORTANT: You must press the RESET button firmly and fully. It should lock into place. If the GFCI does not lock into place, do not use receptacle. Contact a qualified electrician for repairs.

RESET

TEST

Figure 4 - GFCI Receptacle

6

105202

Page 6
Image 6
Master Lock MGH4000CI, MGH5000CI, MGH5000CIE, MGH6000CI, MGH7000CI Generator Features, Oil Alert System, Electric Start