Master Lock High Altitude Operation, Adding Electrical Loads, Disconnecting Electric Loads

Models: HWI3000, MGH3000, MGH4000D, MGH4000DI, MGH5000D, MGH5000DI, MGH5000DIE, MGH6000D, MGH6000DI, MGH7000D, MGH7000DI, MGH10000A MGH4000CI, MGH5000CI, MGH5000CIE, MGH6000CI, MGH7000CI

1 28
Download 28 pages 15.21 Kb
Page 13
Image 13
HIGH ALTITUDE OPERATION

OWNER’S MANUAL

OPERATION

Continued

HIGH ALTITUDE OPERATION

This generator will not perform well at high altitudes without proper adjustment. See engine owner’s manual for details.

ADDING ELECTRICAL

LOADS

IMPORTANT: Do not overload generator. Make sure total wattage of all electrical loads does not exceed rated wattage of gen- erator. Overloading may shorten generator life. It could also cause internal damage to generator. Overloading will trip circuit breaker.

IMPORTANT: (All models except HWI3000, MGH3000, MGH7000D, MGH7000DI, and MGH10000A) Keep full power selector switch in the 120 VOLT ONLY position if only powering 120V items. Only move switch to 120/240 VOLT posi- tion if powering 240V items.

1.Check items to be powered. Their nameplate lists their wattage ratings.

Note: The wattage ratings for some electrical motors are misleading. They may require up to three-times their rated wattage to start. You must figure total electrical load wattage. Make sure total wattage of all electrical loads does not exceed rated wattage of generator. See Determining Electrical Load For Generator, page 10.

2.Start engine. Let engine reach full speed.

3.Connect electrical loads one at a time. If the load consists of electric motors, start them first. Always start the larg- est first. Start each motor individually.

DISCONNECTING ELECTRIC LOADS

Remove electrical loads one at a time. Re- move voltage sensitive items first. Voltage sensitive items include TVs, VCRs, and other home electronic items.

STOPPING ENGINE

IMPORTANT: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle.

Follow the steps below to stop engine.

1.Remove all electrical loads from gen- erator (see Disconnecting Electrical Loads). Remove electrical loads one at a time.

2.Let engine run for two or three min- utes after removing electrical loads. This lets engine cool slightly.

3.Turn engine switch to the OFF posi- tion (see Figure 22).

4.Turn fuel valve lever off. Do this by moving valve lever fully to the left (see Figure 23).

ENGINE SW

ON

OFF

Models HWI3000, MGH3000, MGH4000D,

MGH4000DI, MGH5000D, MGH5000DI,

MGH6000D and MGH6000DI

HONDA

ON

OFF ADDING ELECTRICAL START

ENGINE SW

CIRCUIT

BREAKER

ON/push OFF

Models MGH5000DIE, MGH7000D, MGH7000DI, and MGH10000A

Figure 22 - Engine Switch In OFF Position

Fuel Valve Lever

(Off Position)

Figure 23 - Fuel Valve Lever Off (Model MGH7000D Shown)

105202