Empire Comfort Systems CIBV-30-20 Lighting Instructions, For Your Safety Read Before Lighting

Page 16

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance areaforgas.Besuretosmellnexttothefloorbecausesome gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call yourgas supplierfrom a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance (if appli- cable).

4.Lower valve cover.

5.Push in gas control knob slightly and turn clockwise

to "OFF".

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the

next step.

7.Find pilot - The pilot is attached to the main burner behind the front log.

8.Turn knob on gas control counterclockwise to "PILOT."

9.Push in gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

10.Turn gas control knob counterclockwise to "ON".

11.Raise valve cover.

12.Turn on all electric power to the appliance (if appli- cable).

13.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to appliance if service is to be performed (if applicable).

3.Lower valve cover.

4.Push in gas control knob slightly and turn clock-

wise to "OFF". Do not force.

5.Raise valve cover.

Page 16

15627-5-0807

Image 16
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorIntroduction Specifications CIBV-30Installing a New Main Gas Cock GAS SupplyRecommended Gas Pipe Diameter Checking Manifold PressureInstallation on Rugs and Tile ClearancesAppliance Hardware Package Assembly of Stove CastingDetailed Instructions Follow Assembly of Stove Casting 15627-5-0807 Installation of Optional Stone Inlay Optional Stone Inlay InstallationParts List Wire Channel Installation LOG PlacementVent Safety Shutoff System Operating GuidelinesVenting VentingLiner and Insulated Liner Insulated Vent Enclosure FigureFor Your Safety Read Before Lighting Lighting InstructionsPilot Flame Characteristics Main Burner Flame CharacteristicsAir Shutter Adjustment Cleaning the Log Set and FireboxWiring Maintenance & Service Instructions MaintenanceCleaning Procedure Glass Assembly Replacement Glass CleaningGeneral Glass Information Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsHOW to Order Repair Parts Parts List for CIBV-30-20Parts View for CIBV-30-20 Parts List for Stove Casting Parts View for Stove Casting Optional Blower Installation Instructions Installing Optional CIB-2 BlowerRefer to Wire Channel Installation, Fan ControlCleaning WiringBlower Motor Index Part No. No. DescriptionFAX

CIBV-30-20 specifications

Empire Comfort Systems CIBV-30-20 is a versatile and efficient heating solution designed to meet the needs of both residential and commercial spaces. This direct vent gas fireplace boasts an array of features that make it a popular choice for those looking to enhance their indoor environment with warmth and style.

One of the main features of the CIBV-30-20 is its sleek and contemporary design. The fireplace comes with a clean-faced front that allows for a seamless integration into any decor. Its compact size, with a 30-inch width, makes it suitable for various settings, from cozy living rooms to larger commercial spaces. The large viewing area maximizes the sight of the flames, providing an inviting ambiance and a warm atmosphere.

Performance is a key characteristic of the CIBV-30-20. It operates using natural gas or propane, allowing users to choose the fuel type that best fits their needs. With an impressive heat output of up to 25,000 BTUs, this fireplace efficiently heats the room, ensuring comfort during the cold months. Empire Comfort Systems has engineered the fireplace to deliver consistent and reliable performance, making it an ideal choice for year-round use.

Another significant technology integrated into the CIBV-30-20 is its direct vent system. This feature allows for safe and efficient venting, as it draws air from the outside to fuel the fire, thus eliminating the risk of indoor air pollution. The balanced flue technology ensures that combustion gases are vented outside, maintaining good air quality indoors.

In terms of controls, the CIBV-30-20 is equipped with a reliable millivolt system, which allows for easy operation without the need for electricity. For added convenience, optional remote control kits are available, enabling users to adjust flame height and heat levels from a distance.

The Empire Comfort Systems CIBV-30-20 also prioritizes efficiency. With an efficiency rating of up to 75%, it provides substantial warmth while minimizing energy consumption, making it an eco-friendly heating option.

In summary, the Empire Comfort Systems CIBV-30-20 combines modern aesthetics with advanced heating technology. Its features, including direct vent capability, high heat output, and efficient performance, make it a standout solution for anyone seeking a reliable and stylish heating appliance. Whether for home or business use, the CIBV-30-20 is designed to deliver warmth, comfort, and a welcoming ambiance.