WIRE CHANNEL INSTALLATION
The ON/OFF/REMOTE switch with harness is factory installed into the switch box.
After the appliance housing is installed into the casting the wire channel can be installed.
1.Attach switch box on the left side of rear cover with (2) 10 x 1/2" screws.
2.Route wires from ON/OFF/REMOTE switch within wire channel.
3.Attach wire channel on the left side of the rear cover with (4) 10 x 1/2" screws.
4.Attach the black and green (wires) female push-
ons to the TH/TP and TH (two outside male tabs) terminals on gas valve.
5.Identify vent safety switch wire harness. The first wire is installed into magnet section on gas valve. The second wire is attached to the TH/TP terminal on gas valve. Route opposite end of vent safety switch wire harness within
(2) metal clips on exterior of rear cover. Attach
(2) 1/4" female
Figure 12
LOG PLACEMENT
1. Lower valve cover on firebox.
2. Release two door latches at bottom of firebox.
3. Grasp bottom of glass frame, lift glass frame upward in order to release glass frame from lip on top of firebox.
4.Remove logs from interior of firebox. Remove all protective packaging from logs and interior of firebox.
5.Place front log onto two (2) front pins on inner bottom.
6. Place rear log onto two (2) rear pins on rear log support.
7.Place top log onto two (2) pins on rear log.
8.Align and place top of glass frame over lip on top of firebox. Grasp bottom of glass frame, push inward and place glass frame onto firebox.
9.Attach two door latches to bottom of firebox.
10. Log placement is completed.
Refer to Figure 13 for the following warning.
Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
Avertissement: Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ce schéma et ou si de pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées.
Figure 13
| Page 13 |