WIRE CHANNEL INSTALLATION

The ON/OFF/REMOTE switch with harness is factory installed into the switch box.

After the appliance housing is installed into the casting the wire channel can be installed.

1.Attach switch box on the left side of rear cover with (2) 10 x 1/2" screws.

2.Route wires from ON/OFF/REMOTE switch within wire channel.

3.Attach wire channel on the left side of the rear cover with (4) 10 x 1/2" screws.

4.Attach the black and green (wires) female push-

ons to the TH/TP and TH (two outside male tabs) terminals on gas valve.

5.Identify vent safety switch wire harness. The first wire is installed into magnet section on gas valve. The second wire is attached to the TH/TP terminal on gas valve. Route opposite end of vent safety switch wire harness within

(2) metal clips on exterior of rear cover. Attach

(2) 1/4" female push-ons on vent safety switch wire harness onto (2) 1/4" male tabs on safety switch which is located on the side of draft diverter.

Figure 12

LOG PLACEMENT

1. Lower valve cover on firebox.

2. Release two door latches at bottom of firebox.

3. Grasp bottom of glass frame, lift glass frame upward in order to release glass frame from lip on top of firebox.

4.Remove logs from interior of firebox. Remove all protective packaging from logs and interior of firebox.

5.Place front log onto two (2) front pins on inner bottom.

6. Place rear log onto two (2) rear pins on rear log support.

7.Place top log onto two (2) pins on rear log.

8.Align and place top of glass frame over lip on top of firebox. Grasp bottom of glass frame, push inward and place glass frame onto firebox.

9.Attach two door latches to bottom of firebox.

10. Log placement is completed.

Refer to Figure 13 for the following warning.

Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

Avertissement: Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ce schéma et ou si de pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées.

Figure 13

15627-4-0806

Page 13

Image 13
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction CIBV-30 SpecificationsGAS Supply Installing a New Main Gas CockRecommended Gas Pipe Diameter Checking Manifold PressureClearances Installation on Rugs and TileAppliance Hardware Package Assembly of Stove CastingDetailed Instructions Follow Assembly of Stove Casting 15627-4-0806 Installation of Optional Stone Inlay Optional Stone Inlay InstallationParts List LOG Placement Wire Channel InstallationOperating Guidelines Vent Safety Shutoff SystemVenting VentingLiner and Insulated Liner Insulated Vent Enclosure FigureLighting Instructions For Your Safety Read Before LightingMain Burner Flame Characteristics Pilot Flame CharacteristicsAir Shutter Adjustment Cleaning the Log Set and FireboxWiring Maintenance & Service Instructions MaintenanceCleaning Procedure Glass Assembly Replacement Glass CleaningGeneral Glass Information Frequent pilot outage problem TroubleshootingPilot and main burner extinguish while in operation Glass sootsParts List for CIBV-30-20 HOW to Order Repair PartsParts View for CIBV-30-20 Parts List for Stove Casting Parts View for Stove Casting Installing Optional CIB-2 Blower Optional Blower Installation InstructionsRefer to Wire Channel Installation, Fan ControlWiring CleaningBlower Motor Index Part No. No. DescriptionFAX