Empire Comfort Systems pmn manual Lighting Instructions, For Your Safety Read Before Lighting

Page 16

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance areaforgas.Besuretosmellnexttothefloorbecausesome gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call yourgas supplierfrom a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance (if appli- cable).

4.Lower valve cover.

5.Push in gas control knob slightly and turn clockwise

to "OFF".

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the

next step.

7.Find pilot - The pilot is attached to the main burner behind the front log.

8.Turn knob on gas control counterclockwise to "PILOT."

9.Push in gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

10.Turn gas control knob counterclockwise to "ON".

11.Raise valve cover.

12.Turn on all electric power to the appliance (if appli- cable).

13.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to appliance if service is to be performed (if applicable).

3.Lower valve cover.

4.Push in gas control knob slightly and turn clock-

wise to "OFF". Do not force.

5.Raise valve cover.

Page 16

15627-4-0806

Image 16
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorIntroduction Specifications CIBV-30Installing a New Main Gas Cock GAS SupplyRecommended Gas Pipe Diameter Checking Manifold PressureInstallation on Rugs and Tile ClearancesAppliance Hardware Package Assembly of Stove CastingDetailed Instructions Follow Assembly of Stove Casting 15627-4-0806 Installation of Optional Stone Inlay Optional Stone Inlay InstallationParts List Wire Channel Installation LOG PlacementVent Safety Shutoff System Operating GuidelinesVenting VentingLiner and Insulated Liner Insulated Vent Enclosure FigureFor Your Safety Read Before Lighting Lighting InstructionsPilot Flame Characteristics Main Burner Flame CharacteristicsAir Shutter Adjustment Cleaning the Log Set and FireboxWiring Maintenance & Service Instructions MaintenanceCleaning Procedure Glass Assembly Replacement Glass CleaningGeneral Glass Information Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsHOW to Order Repair Parts Parts List for CIBV-30-20Parts View for CIBV-30-20 Parts List for Stove Casting Parts View for Stove Casting Optional Blower Installation Instructions Installing Optional CIB-2 BlowerRefer to Wire Channel Installation, Fan ControlCleaning WiringBlower Motor Index Part No. No. DescriptionFAX