Installation of Remote Receiver (Figure 20)

Wiring Diagram (Figure 21)

1.Attach, from left to right, the slide-on cover plate onto the remote receiver. ON will be to the top and OFF will be to the bottom on the slide-on cover plate.

2.Push the receiver slide button onto the receiver slide switch. Reverse installation of the slide button if it is off center.

3.Attach velcro loop on the left side of the valve cover support.

4.Attach velcro hook onto remote receiver. The word TOP on the remote receiver should be to the top when installed onto valve cover support.

5.Attach velcro hook on remote receiver onto velcro loop on valve cover support.

Refer to remote control installation and operating instructions for more details on remote control.

Figure 20

.

Figure 21

MAINTENANCE

Maintenance & Service Instructions

IMPORTANT: Turn off gas before servicing appliance. It is recommended that a competent service technician perform these check-ups at the beginning of each heating season.

DO NOT put anything around the heater that will obstruct the flow of combustion and ventilation air. See clearances.

DO examine venting system periodically. Clean and replace damaged parts. Examinations should be made at the start of the heating season and also in mid heating season under average conditions.

Clean Burner and Control Compartment

Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.

Cleaning Procedure

1.Let the unit cool if it has been operating.

2.Shut off gas supply .

3.Lower valve cover on firebox.

4.Release two door latches at bottom of firebox.

5.Grasp bottom of glass frame, lift glass frame upward in order to release glass frame from lip on top of firebox.

6.Vacuumburnercompartmentespeciallyaroundorifice/primary air openings.

7.Align and place top of glass frame over lip on top of firebox. Grasp bottom of glass frame, push inward and place glass frame onto firebox.

8.Attach two door latches to bottom of firebox.

9.Ignite pilot. (See Lighting Instructions)

10.Operate the main burner and visually check to make sure the flame pattern appears similar to the pictorial illustration shown for main burner flame pattern, Figure 18. If it appears abnormal call a service person.

15627-4-0806

Page 19

Image 19
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction CIBV-30 SpecificationsChecking Manifold Pressure Installing a New Main Gas CockGAS Supply Recommended Gas Pipe DiameterClearances Installation on Rugs and TileAppliance Hardware Package Assembly of Stove CastingDetailed Instructions Follow Assembly of Stove Casting 15627-4-0806 Installation of Optional Stone Inlay Optional Stone Inlay InstallationParts List LOG Placement Wire Channel InstallationOperating Guidelines Vent Safety Shutoff SystemInsulated Vent Enclosure Figure VentingVenting Liner and Insulated LinerLighting Instructions For Your Safety Read Before LightingCleaning the Log Set and Firebox Pilot Flame CharacteristicsMain Burner Flame Characteristics Air Shutter AdjustmentWiring Maintenance & Service Instructions MaintenanceCleaning Procedure Glass Assembly Replacement Glass CleaningGeneral Glass Information Glass soots TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationParts List for CIBV-30-20 HOW to Order Repair PartsParts View for CIBV-30-20 Parts List for Stove Casting Parts View for Stove Casting Fan Control Optional Blower Installation InstructionsInstalling Optional CIB-2 Blower Refer to Wire Channel Installation,Index Part No. No. Description CleaningWiring Blower MotorFAX