OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

Installing Optional CIB-2 Blower

1.Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance.

2.Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the appliance.

3.Place the large diameter holes in the keyholes over and behind the (4) hex-head screws that were loosened in Step 1. Push inwardontheblowerassemblytolockthekeyholesintoposition behind the screws. Tighten (4) hex-head screws to secure blower assembly to exterior, bottom of the appliance.

4.Remove wire channel from rear cover by removing (4) hex- head screws. Note: If optional blower is being installed during initial installation of appliance, the wire channel will not be attached to rear cover. (Refer to Wire Channel Installation, Page 13)

5.Attach fan control to FLAT, fan control bracket (Part 9A, Page 27) with (2) 6 x 1/4" screws provided in hardware package.

6.Attach fan control with bracket onto the wire channel by using

(2) 8 x 1/4" screws provided in hardware package.

7.Route wires from fan control and ON/OFF/REMOTE switch within wire channel.

8.When facing the rear of the appliance, align and insert fan control with bracket into 1 3/8" x 2" opening on the left side of the rear cover.

9.Attach wire channel to rear cover by using

(4) hex - head screws removed in Step 4 .

(Refer to Wire Channel Installation, Page 13)

10. Insert AUTO/OFF/ON switch into rectangular notch on valve bracket. Be sure to insert AUTO/OFF/ON switch with letters (words) upright. (See wiring diagram)

11. Attach 1/4" push-on terminal from blue wire on the fan control to the AUTO (top) tab on the switch.

12. Attach 1/4" push-on terminal from black wire to the OFF (middle) tab on the switch.

13. Attach 1/4" push-on terminal from white wire on the fan control to the ON (bottom) tab on the switch.

14. Installation of optional CIB-2 blower is completed.

Fan Control

The fan control is a non-adjustable automatic type. The fan control will require between 5 and 10 minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run between 5 and 10 minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower.

Page 26

15627-4-0806

Image 26
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorIntroduction Specifications CIBV-30Recommended Gas Pipe Diameter Installing a New Main Gas CockGAS Supply Checking Manifold PressureInstallation on Rugs and Tile ClearancesDetailed Instructions Follow Assembly of Stove CastingAppliance Hardware Package Assembly of Stove Casting 15627-4-0806 Parts List Optional Stone Inlay InstallationInstallation of Optional Stone Inlay Wire Channel Installation LOG PlacementVent Safety Shutoff System Operating GuidelinesLiner and Insulated Liner VentingVenting Insulated Vent Enclosure FigureFor Your Safety Read Before Lighting Lighting InstructionsAir Shutter Adjustment Pilot Flame CharacteristicsMain Burner Flame Characteristics Cleaning the Log Set and FireboxWiring Cleaning Procedure MaintenanceMaintenance & Service Instructions General Glass Information Glass CleaningGlass Assembly Replacement Pilot and main burner extinguish while in operation TroubleshootingFrequent pilot outage problem Glass sootsHOW to Order Repair Parts Parts List for CIBV-30-20Parts View for CIBV-30-20 Parts List for Stove Casting Parts View for Stove Casting Refer to Wire Channel Installation, Optional Blower Installation InstructionsInstalling Optional CIB-2 Blower Fan ControlBlower Motor CleaningWiring Index Part No. No. DescriptionFAX