8 Installing Vent Pipe

A. Assembly of Vent Sections (DVP Pipe ONLY)

WARNING

Fire Risk

Exhaust Fumes Risk

Impaired Performance of Appliance

Overlap pipe slip sections at least 1-1/2 inches.

Use pilot holes for screws.

Screws must not exceed one inch long.

Pipe may separate if not properly joined.

Attaching Vent to the Firebox Assembly

To attach the first pipe section to the collars, slide the male end of the inner vent of the pipe section over the inner collar on the firebox assembly. At the same time, slide the outer flue over the outer collar on the appliance. Push the pipe section into the appliance collar until all the lances (see Figure 8.1) have snapped in place. Tug slightly on the section to confirm it has completely locked into place.

Assembling Pipe Sections

Insert the inner flue of section A into the flared inner flue of section B.

Start the outer flue of section A over the outer flue of section B (see Figure 8.2). Note: The end of the pipe sections with the lances/tabs on it will face towards the appliance.

Figure 8.1 Lances

A

B

Figure 8.2

Figure 8.3

Once both inner and outer flues are started, press section A onto section B firmly until all lances have snapped into place. Check to make sure they have snapped together (see Figure 8.3) and the seams are not aligned (see Figure 8.4). Tug slightly on sec- tion A to confirm it has completely locked into place. It is acceptable to use screws no longer than 1 inch to hold outer pipe sections together. If predrilling holes, do NOT penetrate inner pipe.

For 90° and 45° elbows that are changing the vent direction from horizontal to vertical, one screw minimum should be put in the outer flue at the horizontal elbow joint to prevent the elbow from ro- tating. Use screws no longer than 1 inch. If predrilling screw holes, do NOT penetrate inner pipe.

Note: Make sure that the seams are not aligned to prevent unintentional disconnection.

CORRECT

INCORRECT

Figure 8.4 Seams

Hearth & Home Technologies • BE-36-C, BE-36-CIPI397-981 Rev. V 1/07

27

Image 27
Contents What to do if you smell gas BE-36-CIPIHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationModels Clearances Constructing the Appliance ChaseClearances to Mantels or other Combustibles above Appliance Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Minimum Clearances for Termination Alcove ApplicationsMeasuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsUse of Flex Vent Vent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Top Vent Horizontal Termination Three Elbows Baffle Instruction Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 mMinimum H1 Maximum Top Vent Vertical Termination Two Elbows Three ElbowsPage Rear Vent Horizontal Termination- Three elbows Rear Vent Horizontal Termination- Two elbowsRear Vent Horizontal Termination Two elbows Rear Vent Horizontal Termination- One elbowRear Vent Horizontal Termination- Three elbows Non-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Combustible Wall Penetration10 IN. X 10 Installing the Ceiling FirestopInstalling Attic Shield Vertical Penetration FramingChoosing the Top or Rear Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear VentFire Risk Prevent contact with sagging, loose insulation Securing and Leveling the ApplianceAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections DVP Pipe only Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsDVP Pipe only Securing the Vent Sections Vertical SectionsContinue Adding Vent Components Assembly of Vent Sections SL Series Pipe onlyInstall Support Brackets Attach the First Vent Component to Starting CollarsHeat Shield Requirements for Horizontal Termination Installing the Horizontal Termination CapFire Risk. Explosion Risk Installing Roof Flashing and Vertical Termination Cap 20 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceElectrical Information Intellifire Ignition System Wiring Standing Pilot Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFinishing Facing MaterialSee for combustible/non-combustible definitions Remove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-BE-36-C Models BE-36-CShutter Settings Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsLighting Appliance Turn on all electric power to the applianceStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingSympton Possible Cause Corrective Action Intellifire Ignition SystemSure must not exceed 14 in. W.C Maintaining and Servicing Appliance Recommend addition of screen if one is not present Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDVP45 45 Elbow Vent Components DiagramsDVP-TRAP 13-7/8 352 mm 241 mm 24-5/8 625 mm13-1/4 367 mmVertical Termination Cap High wind 98 mm10-1/2 Vertical Termination Cap 184 mm 12-1/2 318 mm 133 mmPipe Length/Inches SL Series Vent ComponentsLog Set Assembly Service PartsIPI System ÎC. Service Parts List BE-36-CAdditional service part numbers may appear on the following Standing PilotStanding Pilot Valve Assembly Service Parts BE-36-CBE-36-CIPI IPI Valve AssemblyHearth & Home Technologies Limited Lifetime WarrantyContact Information
Related manuals
Manual 37 pages 30.79 Kb

BE-36-C specifications

Hearth and Home Technologies, a leader in innovative heating solutions, offers two remarkable gas fireplaces: the BE-36-CIPI and BE-36-C. Both models are designed to deliver efficient heating, aesthetic charm, and user-friendly features, making them ideal for modern living spaces.

The BE-36-CIPI is a direct vent fireplace that provides the warmth of a traditional fire without the hassle of wood. One of its most notable features is its contemporary design, featuring clean lines and a wide viewing area. This model comes with an impressive heat output, ensuring that spaces remain comfortably warm during chilly seasons. The BE-36-CIPI incorporates innovative technologies like the IntelliFire™ ignition system, which promotes energy efficiency by providing reliable performance while minimizing fuel consumption.

Moreover, the fireplace's advanced burner system creates a stunning flame pattern and realistic look, enhancing the ambiance of any room. With customizable options, homeowners can choose different media types, such as ceramic logs or contemporary stones, allowing for personal expression in their décor.

On the other hand, the BE-36-C model offers similar features but with its unique twist. This model is characterized by its traditional aesthetic appeal, making it an excellent choice for those who prefer a classic look with modern convenience. The BE-36-C also utilizes the IntelliFire™ system, ensuring efficiency and ease of use. With a versatile design, this fireplace can fit into various style preferences, from rustic to modern.

Both models come equipped with optional heat management systems, allowing for effective temperature regulation. This feature is particularly useful for maintaining a comfortable environment without overheating the space. The fireplaces are also designed with safety in mind, adhering to strict safety standards and offering numerous safety features like a safety pilot and tempered glass doors.

In conclusion, Hearth and Home Technologies’ BE-36-CIPI and BE-36-C gas fireplaces present an ideal blend of aesthetics, efficiency, and advanced technology. Whether opting for the contemporary style of the BE-36-CIPI or the classic allure of the BE-36-C, homeowners are guaranteed to enjoy a superior heating experience that complements their home’s design while providing warmth and comfort.