Gas Requirements
GENERAL INFORMATION
Never attach an unregulated gas line to the appliance. Connection to an unregulated gas line can cause excessive heat or fire.
Verify the type of gas supply to be used, either Natural Gas (N.G.) or Liquid Propane (L.P.), and make sure the serial plate agrees with that of the supply. Conversion kits are available separately for an additional cost which will enable you to convert your grill from L.P. to N.G. or to convert your grill from N.G. to L.P. Please see your local dealer for more information.
NOTE: Always have a qualified service technician perform difficult conversions or modifications.
For natural gas installations, an installer must supply a gas shutoff valve that is easily accessible to the grill. All installer sup- plied parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70- 1990, and the National Fuel Gas Code, ANSI
All pipe sealants must be an approved type and resistant to the actions of L.P. gases. Never use pipe sealant on
flare fittings. All gas connections should be made by a competent qualified service technician and in accordance with local codes and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code, ANSI
This grill and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa.).
This grill must be isolated from the gas supply piping system by closing its individual manual
The installation of this grill must conform with local codes, or in the absence of local codes, with National Fuel Code, ANSI
Installation in Canada must be in accordance with the Standard
NATURAL GAS INSTALLATION
The gas inlet supply pressure should be between 5” and 14” water column,(w.c.) A step down regulator is required if the line pressure is in excess of 14” w.c. Inlet pressure must not exceed 14” water column (1/2 PSIG)
Check your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run, and how deep to bury the line. If the gas supply line is too small, the grill will not operate correctly.
Any joint sealant used must be an approved type and be resistant to chemical breakdown resulting from the reaction with N.G.
Attach the natural gas regulator (supplied with your grill) to the brass fitting coming out the bottom, right side of the grill (be sure the arrow on the regulator is pointing up towards the grill). Attach your gas line to the 3/8” flare fitting coming out of the natural gas regulator under the grill.
NOTE: The gas line connection and the gas fitting must be the same diameter.
Installer supplied
NOTE: A flexible natural gas line is not included with Frigidaire Gallery grills. Natural gas flex line must be purchased separately based on the distance of your grill location from the natural gas line. Please be sure to check the size of your home’s natural gas line fitting to make sure you get the right size connection for your particular application. If you have questions, please consult your local natural gas distributor or qualified service technician.
9