Conversion to LPG
Replacing the injectors
1.Remove the pan supports.
2.Remove the burner caps and crowns.
3.Using a 7 mm socket spanner unscrew and remove the injectors, then replace them with the ones required for the new type of gas (see the table “Burner characteristics”).
4.Reassemble the parts, following the same procedure backwards.
5.Replace the Gas Type Label (located near the gas supply connection) with the one corresponding to the new type of gas. The label is supplied in the accessories plastic bag.
Should the feeding gas pressure be different or variable compared with the required pressure, an appropriate pressure regulator must be fitted on the gas supply pipe, in compliance with the rules in force.
Burner characteristics
GAS | BURNER | INJECTOR | NOMINAL | REDUCED | NOMINAL | FEEDING | ||
TYPE | TYPE | REFERENCE | THERMAL | THERMAL | FLOW RATE | PRESSURE | ||
|
| 1/100 mm | POWER | POWER |
|
|
| |
|
| m3/h |
|
| ||||
|
|
| kW | kW | g/h | mbar | ||
NATURAL | Rapid | 119 | 2.9 | 0.65 | 0.276 |
|
| |
GAS | Semirapid | 96 | 1.9 | 0.45 | 0.181 | - | 20 | |
(G 2 0 ) | Auxiliary | 70 | 1.0 | 0.33 | 0.095 | - |
| |
|
| |||||||
|
|
|
|
|
|
|
| |
LIQUID | Rapid | 86 | 2.7 | 0.65 | - | 196 |
| |
GAS |
| |||||||
Semirapid | 71 | 1.9 | 0.45 | - | 138 | |||
(Butane/ | ||||||||
Auxiliary | 50 | 1.0 | 0.33 | - | 73 |
| ||
Propane) |
| |||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
32