INSTALLATION INSTRUCTIONS

Be sure the appliance is properly installed and grounded by a qualified technician. It is the responsibility of the technician to be certain that your range is properly installed. Situations caused by improper installation are not covered under the warranty. Any expenses incurred due to such situations will not be paid by the manufacturer of the appliance.

WARNING: To reduce the risk of tipping the appliance by abnormal usage or improper door loading, the appliance must be secured by properly installing the anti-tip device packed with the appliance. To check if the device is installed and engaged properly, carefully tip the range forward. The anti-tip device should engage and prevent the range from tipping over.

If this range is removed for any reason, service or cleaning etc,. it must be replaced as outlined in the installation instructions, before placing the range back in operation.

LEVELING A FREE

STANDING RANGE

All free-standing ranges must be level to obtain proper cooking results. The leveling legs should be screwed into the corner brackets. Place a level, or a pan or measuring cup partially filled with water, level on oven rack. Adjust leveling legs until the range is level. The top of the side panels should be level with countertop or work surface.

IMPORTANT: Be sure to keep the leg levelers. Leveling of the range is very important.

GAS CONNECTIONS

Have the dealer where you purchased your new range install or recommend a qualified installer. Installation must conform with local codes. The range should be connected to a supply line with 1/2-inch black iron pipe or a certified flexible type stove connector. To prevent gas leaks, put an approved sealing compound, which is resistant to liquefied gases, on all threaded connections.

IMPORTANT: Do not apply pressure directly to the range manifold pipe when tightening supply connections. The manifold pipe should be held securely at the pressure regulator to prevent twisting. Hold the pressure regulator with a wrench during the tightening of the connection, or the manifold pipe may be twisted and split, causing a dangerous leak.

Note: The installation of ranges designed for manufactured (mobile) homes must conform to specific standards and local codes.Check all piping connections in the unit for leaks. Never use an open flame to check for gas leaks. It is possible for connections made at the factory to leak due to vibrations encountered in transportation. Have any suspected leaks repaired before use by a qualified service personnel.

ELECTRICAL

Your range is grounded with a three-conductor (three-prong plug) supply cord which

CONNECTIONS

will ground the range when plugged into a similar grounded wall receptacle.

 

 

If the backgaurd of the range has a clock or light, connect the cord from the backgaurd into the special terminal block located at the top of the main back directly under the backgaurd supply cord.The appliance must be electrically grounded when installed in accordance with local codes.

5

Image 6
Contents DR2099W/BL GLP Welcome Please do this NOWResulting in property damage, personal injury, or death What to do if YOU Smell GAS Important Safety InformationProper Installation Before First USEImportant Safety Information cont’d Important SafegaurdsEnergy Saving Tips Surface CookingOven Cooking GAS Connections Installation InstructionsLeveling a Free Standing Range ElectricalUsing Your Range Operating InstructionsFlame Size Type of Cooking Using Your Operating Instructions cont’dNO. of Pans Position on Rack Care and Cleaning Setting Clock & TimerCare and Cleaning cont’d Troubleshooting Problem Possible Cause SolutionLimited Warranty GAS Range Bienvenida Sírvase Realizar LO Siguiente AhoraQUÉ Hacer SI Huele a GAS InstallaciónInformacion Importantes DE Seguridad Antes DE Utiliza PrimeroInformacion Importantes DE Seguridad cont’d Medidas DE Protección ImportantesConsejos Paraahorrar Energía Cocción en las hornillasCocción en el horno Conexiones DE GAS Instrucciones DE InstalaciónCómo Nivelar UNA Cocina Independiente ConexionesInstrucciones Operadoras Cómo Usar LA CocinaTipo DE Cocción Posición EN LA Bandeja Instrucciones Operadoras cont’dCómo Usar LA Centro del bandejaPara ajustar el reloj de hora de 4 botones Cuidados Y LimpiezaAjuste DEL Reloj Y EL Temporizador Para ajustar el temporizador de minutos de 4 botonesCuidados Y Limpieza cont’d Problema Posible Causa Solución Antes DE Llamar AL Servicio TécnicoCocinas DE GAS Garantía Limitada Bienvenue Installation Appropriée Consignes DE Sécurité ImportantesAvant Première Utilisation Consignes DE Sécurité Importantes suite DE SécuritéSuggestions Économiser Dénergie Cuisson au dessus de la cuisinièreCuisson au four Instructions Dinstallation Mise À Niveau D’UNE Cuisinière AutostableRaccords DE GAZ Consignes D’UTILISATION Utiilisation DE Votre CuisinièreDisposer SUR Grilles Consignes D’UTILISATION suiteUtiilisation DE Votre CasserolesSoins ET Entretien Réglage DE L’HORLOGE ET DE LA MinuteriePorte de four de décollage Surface de fourCavité de four Nettoyage de la porte intérieureDépannage Les brûleurs du dessus deGarantie Limitée DE Cuisinière À GAZ GAS Range Cuisinière DE GAZCocina DE GAS

DR2099WGLP, DR2099BLGLP specifications

The Danby DR2099BLGLP and DR2099WGLP are two versatile and efficient portable air conditioners designed to provide relief from heat and humidity in various settings. Ideal for small to medium-sized rooms, these units are engineered to deliver comfort without compromising portability or performance.

One of the standout features of both models is their impressive cooling capacity. With a powerful 9,000 BTU rating, they are capable of cooling spaces of approximately 350 square feet, making them perfect for bedrooms, living rooms, or home offices. The energy-efficient design ensures that while they effectively lower temperatures, they also maintain relatively low energy consumption, potentially reducing your electricity bills.

The Danby DR2099 series incorporates advanced cooling technologies such as automatic restart and a programmable timer. These features allow users to set specific cooling schedules, ensuring that the space is comfortable upon arrival without constant manual adjustments. Additionally, the auto-restart function means that in the event of a power outage, the unit will revert to its last settings once power is restored, providing added convenience for users.

Both models come equipped with a user-friendly interface that includes an easy-to-read LED display and remote control, allowing users to adjust settings from a distance. The multi-functional design of the units also includes dehumidification and fan-only modes, making them useful year-round, regardless of the weather outside.

The portability of the Danby DR2099 units is another key feature, as they are designed with caster wheels and integrated handles, allowing easy movement from room to room. Their compact size means they can fit into tighter spaces without sacrificing cooling efficiency.

Furthermore, the air conditioners feature a washable and reusable air filter, promoting cleaner air quality and reducing the need for frequent replacements. This not only extends the life of the unit but also contributes to its overall sustainability.

In summary, the Danby DR2099BLGLP and DR2099WGLP are excellent choices for anyone seeking an efficient and user-friendly cooling solution. Their combination of powerful performance, advanced features, portability, and eco-friendliness makes them stand out in the crowded market of portable air conditioning.