Installation Instructions

ELECTRICAL CONNECTIONS

ELECTRICAL REQUIREMENTS

CAUTION: For personal safety, do not use an extension cord with this appliance. Remove house fuse or open circuit breaker before beginning installation.

This appliance must be supplied with the proper voltage and frequency, and connected to an individual properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as specified on the rating plate. The rating plate is located under the cooktop. See the Lift-Up Cooktop section

in this manual for instructions on how to lift the cooktop.

Rating Plate

We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you where your main range disconnect is located.

Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your range must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70– Latest Edition. You can get a copy by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA 02269

Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range.

ELECTRICAL REQUIREMENTS (cont.)

When installing an electric range in new construction, follow Steps 3 and 5 for 4-wire connection.

You must use a 3-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used.

If the electrical service provided does not meet the above specifications, have a licensed electrician install an approved outlet.

ALL NEW BRANCH CIRCUIT

INSTALLATIONS, MOBILE

HOMES, RECREATIONAL

VEHICLES AND

INSTALLATIONS WHERE

LOCAL CODES DO NOT

ALLOW GROUNDING

THROUGH NEUTRAL,

REQUIRE A 4-CONDUCTOR

CORD OR CONDUIT

Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device.

A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal 138diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable.

Because range terminals are not accessible after range is in position, flexible service conduit or cord must be used.

NOTE: If conduit is being used, go to Step 3D and then to Step 6 or 7.

On some models, a filter capacitor may be connected between the black and white leads on the junction block.

15

Image 15
Contents Write the model and serial numbers here Model # Serial # 20″ and 24″ Compact Electric RangesAll ranges can tip and injury could result ANTI-TIP DeviceOperating Instructions Care and Cleaning Installation InstructionsGe.com Medium High heats Consumer SupportUsing the surface units Tips Installation Instructions Oven Shelf Positions Using the ovenInstructions Safety Instructions Oven Temperature ControlPreheating Using the oven for baking or roastingHow to Set Your Oven for Baking or Roasting Shelf PositionsType of margarine will affect baking performance Adjust the oven thermostat-Easy to do yourselfSafety Instructions Consumer Support Troubleshooting TipsClose the door. Always broil with the door closed Using the oven for broilingHow to Set Your Oven for Broiling Broiling GuideSurface Units and Drip Pans Care and cleaning of the rangePorcelain Enamel Cooktop Oven ShelvesOven Heating Elements Lift-Up Cooktop SafetyTroubleshooting Tips Lift-Off Oven Door Porcelain Oven Interior Instructions Safety Control Knobs Instructions Painted SurfacesRead these instructions completely and carefully For Your SafetyBefore YOU Begin ANTI-TIP DeviceRemove Shipping Materials Materials YOU MAY NeedTools YOU will Need Parts IncludedElectrical Requirements Electrical ConnectionsDo not discard this screw Power Cord and Strain Relief InstallationAfter Do not remove the ground strap connectionCut and discard the ground strap. do not Discard ANY Screws BeforeWire Conduit Installation Replace the Wire CoverWire used, location and enclosure Level the Range ANTI-TIP Device InstallationProblem Possible Causes What To Do Before You Call For Service…We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration We Will Replace Electric Range WarrantyWhat is Not Covered Care and CleaningReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website