GE RGA620 Important Safety Notice, ANTI-TIP Device, Operating Instructions Safety Instructions

Page 2

Operating Instructions Safety Instructions

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

IMPORTANT SAFETY NOTICE

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the state to cause cancer, birth defects or other reproductive harm, and requires businesses to warn customers of potential exposure to such substances.

Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly adjusted burners, indicated by a bluish rather than a yellow flame, will minimize incomplete combustion. Exposure to these substances can be minimized by venting with an open window or using a ventilation fan or hood.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Service must be performed by a qualified service agency.

Installations must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the state, province, or region where this appliance is being installed.

Only use gas shut-off valves approved for use within the state, province or region where this appliance is being installed.

In Massachusetts, a flexible gas connector, when used, must not exceed 3 feet.

WARNING!

ANTI-TIP DEVICE

ALL RANGES CAN TIP

INJURY TO PERSONS COULD RESULT

INSTALL ANTI-TIP

DEVICES PACKED WITH

RANGE

SEE INSTALLATION INSTRUCTIONS

®

2

Image 2
Contents 20″ and 24″ Compact Gas Ranges ANTI-TIP Device Important Safety NoticeOperating Instructions Safety Instructions Page Safety Precautions Cook Meat and Poultry THOROUGHLY…Oven Surface Cooking Units Operating Instructions Care and Cleaning Installation InstructionsTroubleshooting Tips Consumer Support Flooring Under the RangeInstructions Using the surface burnersCleaning Lighting Instructions for Electric Ignition ModelsTop of Range Cookware SafetyHow to Select Flame Size Power Outage-Electric Ignition Models Cleaning Operating Using the ovenInstructions Safety Instructions Consumer Support Power Outage-Standing Pilot ModelsOven Control Air AdjustmentCare and Cleaning Oven ShelvesInstructions Care and Cleaning Oven Vents Oven Shelf PositionsUsing the oven for baking Cookies Cleaning Operating Oven ShelvesTips Installation Cakes PiesHow to Set the Oven For Roasting Using the oven for roastingAdjust the oven thermostat knob-Do it yourself To Adjust the ThermostatHow to Set Your Oven for Broiling Using the oven for broilingSafety Instructions Broiling Guide Safety Instructions OperatingTips Installation Instructions Lift-Up Cooktop Care and cleaning of the rangeHow to Remove the Range for Cleaning and Servicing Rinse with clean waterControl Panel and Knobs Control knobs may be removed for easier cleaningBurners Metal PartsBroiler Compartment Instructions Safety Removable Oven BottomCleaning the Oven Bottom To remove the broiler panBroiler Pan and Grid Safety Lift-Off Oven DoorLet the range cool before cleaning Painted SurfacesSafety Instructions Operating Installation of the rangeFor Your Safety Instructions Troubleshooting Tips Consumer SupportCare and Cleaning Operating Instructions Tools YOU will NeedTroubleshooting Tips Consumer Dimensions and ClearancesSafety Instructions Range Location Recommended gas and electric supply locationSupport Anti-Tip Bracket Installation InstructionsAnti-Tip Bracket Convert the Pressure Regulator Burner SpecificationsPrepare Range for Conversion Tools RequiredAdjusting the Air Shutter Converting the Surface BurnersIf the range has standing pilots Adjust the Oven PilotQuality of Flames Tips Consumer Support Connect the Range to GasChecking Manifold Gas Pressure Electrical Grounding Instructions Operating InstructionsIf Range Has Electric Ignition Light the Oven Pilot on standing pilot modelsLeveling the Range Oven Burner Air Shutter AdjustmentIf adjustments are necessary Mobile Home Installation When All Hookups Are CompleteOperating Instructions Care and Cleaning Protect Your FloorBefore You Call For Service… Safety Instructions Operating Instructions Care and Cleaning Care and Cleaning Operating Instructions Safety Instructions We Will Replace Gas Range WarrantyWhat is Not Covered One YearConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio
Related manuals
Manual 36 pages 46.72 Kb

RGA624, RGA620 specifications

The General Electric (GE) RGA620 and RGA624 are advanced radiation survey meters designed for professionals in nuclear facilities, environmental monitoring, and emergency response. These devices offer robust performance and innovative features that enhance user experience and ensure precise radiation detection.

At the core of the RGA620 and RGA624 are highly sensitive Geiger-Müller (GM) tubes, which allow for the detection of alpha, beta, and gamma radiation. This versatility makes them suitable for a wide range of applications, from laboratory research to field measurements in emergency situations. Both models feature a broad energy response, enabling accurate detection across varying radiation energies.

One of the standout features of the RGA620 and RGA624 is their digital display, which provides clear and easily readable results. The intuitive interface allows users to quickly access measurement functions, change settings, and view real-time data. Alongside this, the devices are equipped with audible alarms, providing instant alerts when radiation levels exceed predefined thresholds, ensuring timely response during critical situations.

Both models utilize advanced data logging capabilities, enabling users to store measurement data for future analysis or compliance reporting. This feature is particularly valuable in regulatory environments where documentation of radiation levels is crucial. The RGA620 and RGA624 can also connect to external software for further data management, enhancing operational efficiency.

In terms of durability, the RGA620 and RGA624 are designed with rugged housing that meets stringent industrial standards. Their lightweight and portable design make them suitable for fieldwork, allowing professionals to conduct radiation surveys effortlessly. The devices are also designed for easy maintenance, with replaceable batteries and straightforward calibration processes.

Enhanced connectivity options, including USB ports, allow for easy data transfer and integration with other monitoring systems. This adaptability ensures that the RGA620 and RGA624 can be an integral part of a comprehensive radiation safety program.

Overall, the GE RGA620 and RGA624 are exemplary tools in radiation detection technology. Their combination of sensitivity, user-friendly features, and robust design make them essential for professionals working in environments where radiation monitoring is paramount. With these instruments, users can ensure safety, compliance, and effective management of radiation risks.