FLOORING UNDER THE RANGE

Do not locate the range where it may be subject to strong drafts. Any openings in the floor or wall behind the range should be sealed. Make sure the openings around the base of the range that supply fresh air for combustion and ventilation are not obstructed by carpeting or woodwork.

Safety Instructions

Your range, like many other household items, is heavy and can settle into soft floor coverings such as cushioned vinyl or carpeting. Use care when moving the range on this type of flooring. It is recommended that the following simple and inexpensive instructions be followed to protect your floor.

The range should be installed on a sheet of plywood (or similar material). When the floor covering ends at the front of the range, the area that the range will rest on should be built up with plywood to the same level or higher than the floor covering.

This will allow the range to be moved for cleaning or servicing. Also, make sure your floor covering will withstand 180°F. (See the Installation Safety Instructions section).

Make sure the wall coverings around your range can withstand the heat generated (up to 200°F) by the range. (See the Installation Safety Instructions section).

Operating Instructions Care and Cleaning

LEVELING THE RANGE

Leveling legs are located on each corner of the base of the range. Your range must be level in order to produce proper cooking and baking results. After it is in its final location, place a level horizontally on any oven shelf and check the levelness front to back and side to side. Level the range by adjusting the leveling legs or by placing shims under the corners as needed.

One of the rear leveling legs will engage the Anti-Tip device (allow for some side to side adjustment). Allow a minimum clearance of 1/8 inch between the range and the leveling leg that is to be installed into the Anti-Tip device.

Installation Instructions

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

7

Troubleshooting Tips Consumer Support

Image 7
Contents 20″ and 24″ Compact Gas Ranges Operating Instructions Safety Instructions Important Safety NoticeANTI-TIP Device Page Cook Meat and Poultry THOROUGHLY… Safety PrecautionsOven Surface Cooking Units Flooring Under the Range Installation InstructionsTroubleshooting Tips Consumer Support Operating Instructions Care and CleaningLighting Instructions for Electric Ignition Models Using the surface burnersCleaning InstructionsHow to Select Flame Size SafetyTop of Range Cookware Consumer Support Power Outage-Standing Pilot Models Using the ovenInstructions Safety Instructions Power Outage-Electric Ignition Models Cleaning OperatingOven Shelves Air AdjustmentCare and Cleaning Oven ControlOven Shelf Positions Instructions Care and Cleaning Oven VentsUsing the oven for baking Pies Cleaning Operating Oven ShelvesTips Installation Cakes CookiesTo Adjust the Thermostat Using the oven for roastingAdjust the oven thermostat knob-Do it yourself How to Set the Oven For RoastingSafety Instructions Using the oven for broilingHow to Set Your Oven for Broiling Instructions Operating Broiling Guide SafetyRinse with clean water Care and cleaning of the rangeHow to Remove the Range for Cleaning and Servicing Tips Installation Instructions Lift-Up CooktopMetal Parts Control knobs may be removed for easier cleaningBurners Control Panel and KnobsTo remove the broiler pan Instructions Safety Removable Oven BottomCleaning the Oven Bottom Broiler CompartmentLift-Off Oven Door Broiler Pan and Grid SafetyPainted Surfaces Let the range cool before cleaningInstructions Troubleshooting Tips Consumer Support Installation of the rangeFor Your Safety Safety Instructions OperatingTools YOU will Need Care and Cleaning Operating InstructionsSafety Instructions Dimensions and ClearancesTroubleshooting Tips Consumer Recommended gas and electric supply location Range LocationAnti-Tip Bracket Anti-Tip Bracket Installation InstructionsSupport Tools Required Burner SpecificationsPrepare Range for Conversion Convert the Pressure RegulatorConverting the Surface Burners Adjusting the Air ShutterQuality of Flames Adjust the Oven PilotIf the range has standing pilots Checking Manifold Gas Pressure Connect the Range to GasTips Consumer Support Operating Instructions Electrical Grounding InstructionsLight the Oven Pilot on standing pilot models If Range Has Electric IgnitionIf adjustments are necessary Oven Burner Air Shutter AdjustmentLeveling the Range Protect Your Floor When All Hookups Are CompleteOperating Instructions Care and Cleaning Mobile Home InstallationBefore You Call For Service… Safety Instructions Operating Instructions Care and Cleaning Care and Cleaning Operating Instructions Safety Instructions One Year Gas Range WarrantyWhat is Not Covered We Will ReplaceReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website
Related manuals
Manual 36 pages 46.72 Kb

RGA624, RGA620 specifications

The General Electric (GE) RGA620 and RGA624 are advanced radiation survey meters designed for professionals in nuclear facilities, environmental monitoring, and emergency response. These devices offer robust performance and innovative features that enhance user experience and ensure precise radiation detection.

At the core of the RGA620 and RGA624 are highly sensitive Geiger-Müller (GM) tubes, which allow for the detection of alpha, beta, and gamma radiation. This versatility makes them suitable for a wide range of applications, from laboratory research to field measurements in emergency situations. Both models feature a broad energy response, enabling accurate detection across varying radiation energies.

One of the standout features of the RGA620 and RGA624 is their digital display, which provides clear and easily readable results. The intuitive interface allows users to quickly access measurement functions, change settings, and view real-time data. Alongside this, the devices are equipped with audible alarms, providing instant alerts when radiation levels exceed predefined thresholds, ensuring timely response during critical situations.

Both models utilize advanced data logging capabilities, enabling users to store measurement data for future analysis or compliance reporting. This feature is particularly valuable in regulatory environments where documentation of radiation levels is crucial. The RGA620 and RGA624 can also connect to external software for further data management, enhancing operational efficiency.

In terms of durability, the RGA620 and RGA624 are designed with rugged housing that meets stringent industrial standards. Their lightweight and portable design make them suitable for fieldwork, allowing professionals to conduct radiation surveys effortlessly. The devices are also designed for easy maintenance, with replaceable batteries and straightforward calibration processes.

Enhanced connectivity options, including USB ports, allow for easy data transfer and integration with other monitoring systems. This adaptability ensures that the RGA620 and RGA624 can be an integral part of a comprehensive radiation safety program.

Overall, the GE RGA620 and RGA624 are exemplary tools in radiation detection technology. Their combination of sensitivity, user-friendly features, and robust design make them essential for professionals working in environments where radiation monitoring is paramount. With these instruments, users can ensure safety, compliance, and effective management of radiation risks.