GE RGA620, RGA624 owner manual Electrical Grounding Instructions, Operating Instructions

Page 32

Safety Instructions

Installation of the range.

Read these instructions completely and carefully.

To Make Electrical Connection (if range has electric ignition)

Operating Instructions

CAUTION—FOR PERSONAL SAFETY: DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded and polarized branch circuit, protected by a circuit breaker or time-delay fuse, as noted on the rating plate.

Wiring must conform to National Electrical Codes or the prevailing local code for a range of this kilowatt rating. (See the rating plate under the cooktop for this information.)

If the electric supply provided does not meet the above specifications, call a licensed electrician.

Installation Instructions Care and Cleaning

WARNING!

Electrical Grounding Instructions

This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug.

INSURE PROPER GROUND EXISTS BEFORE USE.

Light and Adjust Surface Burner Pilots (if range has standing pilots)

Consumer Support Troubleshooting Tips

Purge all air from the supply system by setting one of the surface burner control knobs to HI for 15 seconds.

Turn the surface burner control knob to OFF and light the pilot burners with a match. (See the Lighting Instructions for Standing Pilot Models in the Using the surface burners section in this Owner's Manual.) Adjust pilot flames using the adjusting screw, accessed through a hole in the front right side of the burner box under the cooktop, so that each flame is approximately 1/4-inch in height.

To light any top burner, push and turn burner knob to the LITE position.

When burner has ignited, rotate knob to desired flame setting.

To adjust the pilots, lift and prop open the cooktop. Then use a small flat-bladed screwdriver to turn the adjusting screw (accessed through a hole in the front right side of the burner box).

Pilot adjustment

32

Image 32
Contents 20″ and 24″ Compact Gas Ranges ANTI-TIP Device Important Safety NoticeOperating Instructions Safety Instructions Page Safety Precautions Cook Meat and Poultry THOROUGHLY…Oven Surface Cooking Units Installation Instructions Troubleshooting Tips Consumer SupportOperating Instructions Care and Cleaning Flooring Under the RangeUsing the surface burners CleaningInstructions Lighting Instructions for Electric Ignition ModelsTop of Range Cookware SafetyHow to Select Flame Size Using the oven Instructions Safety InstructionsPower Outage-Electric Ignition Models Cleaning Operating Consumer Support Power Outage-Standing Pilot ModelsAir Adjustment Care and CleaningOven Control Oven ShelvesInstructions Care and Cleaning Oven Vents Oven Shelf PositionsUsing the oven for baking Cleaning Operating Oven Shelves Tips Installation CakesCookies PiesUsing the oven for roasting Adjust the oven thermostat knob-Do it yourselfHow to Set the Oven For Roasting To Adjust the ThermostatHow to Set Your Oven for Broiling Using the oven for broilingSafety Instructions Broiling Guide Safety Instructions OperatingCare and cleaning of the range How to Remove the Range for Cleaning and ServicingTips Installation Instructions Lift-Up Cooktop Rinse with clean waterControl knobs may be removed for easier cleaning BurnersControl Panel and Knobs Metal PartsInstructions Safety Removable Oven Bottom Cleaning the Oven BottomBroiler Compartment To remove the broiler panBroiler Pan and Grid Safety Lift-Off Oven DoorLet the range cool before cleaning Painted SurfacesInstallation of the range For Your SafetySafety Instructions Operating Instructions Troubleshooting Tips Consumer SupportCare and Cleaning Operating Instructions Tools YOU will NeedTroubleshooting Tips Consumer Dimensions and ClearancesSafety Instructions Range Location Recommended gas and electric supply locationSupport Anti-Tip Bracket Installation InstructionsAnti-Tip Bracket Burner Specifications Prepare Range for ConversionConvert the Pressure Regulator Tools RequiredAdjusting the Air Shutter Converting the Surface BurnersIf the range has standing pilots Adjust the Oven PilotQuality of Flames Tips Consumer Support Connect the Range to GasChecking Manifold Gas Pressure Electrical Grounding Instructions Operating InstructionsIf Range Has Electric Ignition Light the Oven Pilot on standing pilot modelsLeveling the Range Oven Burner Air Shutter AdjustmentIf adjustments are necessary When All Hookups Are Complete Operating Instructions Care and CleaningMobile Home Installation Protect Your FloorBefore You Call For Service… Safety Instructions Operating Instructions Care and Cleaning Care and Cleaning Operating Instructions Safety Instructions Gas Range Warranty What is Not CoveredWe Will Replace One YearSchedule Service Parts and AccessoriesConsumer Support GE Appliances Website Real Life Design Studio
Related manuals
Manual 36 pages 46.72 Kb

RGA624, RGA620 specifications

The General Electric (GE) RGA620 and RGA624 are advanced radiation survey meters designed for professionals in nuclear facilities, environmental monitoring, and emergency response. These devices offer robust performance and innovative features that enhance user experience and ensure precise radiation detection.

At the core of the RGA620 and RGA624 are highly sensitive Geiger-Müller (GM) tubes, which allow for the detection of alpha, beta, and gamma radiation. This versatility makes them suitable for a wide range of applications, from laboratory research to field measurements in emergency situations. Both models feature a broad energy response, enabling accurate detection across varying radiation energies.

One of the standout features of the RGA620 and RGA624 is their digital display, which provides clear and easily readable results. The intuitive interface allows users to quickly access measurement functions, change settings, and view real-time data. Alongside this, the devices are equipped with audible alarms, providing instant alerts when radiation levels exceed predefined thresholds, ensuring timely response during critical situations.

Both models utilize advanced data logging capabilities, enabling users to store measurement data for future analysis or compliance reporting. This feature is particularly valuable in regulatory environments where documentation of radiation levels is crucial. The RGA620 and RGA624 can also connect to external software for further data management, enhancing operational efficiency.

In terms of durability, the RGA620 and RGA624 are designed with rugged housing that meets stringent industrial standards. Their lightweight and portable design make them suitable for fieldwork, allowing professionals to conduct radiation surveys effortlessly. The devices are also designed for easy maintenance, with replaceable batteries and straightforward calibration processes.

Enhanced connectivity options, including USB ports, allow for easy data transfer and integration with other monitoring systems. This adaptability ensures that the RGA620 and RGA624 can be an integral part of a comprehensive radiation safety program.

Overall, the GE RGA620 and RGA624 are exemplary tools in radiation detection technology. Their combination of sensitivity, user-friendly features, and robust design make them essential for professionals working in environments where radiation monitoring is paramount. With these instruments, users can ensure safety, compliance, and effective management of radiation risks.