Control Lockout

Your control will allow you to lock down the touch pads so they cannot be activated when pressed.

 

Press the BAKE and BROIL HI/LO pads at the same

1

 

time for 2 seconds until the display shows “SF.”

 

Press the SELF CLEAN pad. The display will show

2

 

“LOC OFF.”

 

Press the SELF CLEAN pad again. The display will

 

show “LOC ON.”

 

Press the START pad to activate the control lockout

3

 

feature and leave the control set in this special

features mode.

When this feature is on and the touch pads are pressed the control will beep and the display will show “LOC.”

NOTE: The control lockout mode will not affect the clock and timer pads.

Tones at the End of a Timed Cycle

At the end of a timed cycle, 3 short beeps will sound followed by one beep every 6 seconds, until the CLEAR/OFF pad is pressed. This continuous 6 second beep may be canceled.

To cancel the 6 second beep:

 

Press the BAKE and BROIL HI/LO pads at the same

1

 

time for 2 seconds until the display shows “SF.”

2 Press the KITCHEN TIMER ON/OFF pad. The display shows “CON BEEP” (continuous beep). Press the KITCHEN TIMER ON/OFF pad again. The display shows “BEEP.” (This cancels the one beep every 6 seconds.)

3 Press the START pad.

Safety Information Operating Instructions Installation Instructions Troubleshooting Tips Customer Service

19

Image 19
Contents GE Answer Center GE AppliancesProof of the original purchase date Staple sales slip or cancelled check hereCongratulations You Are Now Part of the GE Family Write the model and serial numbers hereGE & You Service Partnership All ranges can tip and injury could result Safety Precautions Safety Information Cook Meat and Poultry THOROUGHLY… Instructions Troubleshooting Tips Customer ServiceOven SELF-CLEANING Oven Surface Cooking Units Troubleshooting Tips Customer Service Safety Information Operating Instructions InstallationRead and follow this Safety Information carefully How to Set Using the surface unitsWok Cooking Do not use the surface as a cutting board Dual Surface Unit Switch glass cooktops onlySelecting types of cookware. glass cooktops only Clock and Timer Features Using the oven controlsOven Control Settings Hour Shut-Off Special features of your oven controlTones at the End of a Timed Cycle Control LockoutYour control is set to use a 12 hour clock Hour, 24 Hour or Clock Black-OutChanging the Speed of the + or Pads Cook and HoldHow to Set the Oven for Baking or Roasting Using the ovenBefore you begin… Aluminum Foil Preheating and Pan PlacementHow to Set the Oven for Broiling Troubleshooting Tips Customer ServiceComments Broiling guideTo Cancel the Timer Using the clock and timerTo Set the Timer To Reset the TimerMake sure the oven clock shows the correct time of day How to Set an Immediate Start Automatic StopHow to Set a Delay Start and Automatic Stop To Adjust the Thermostat Adjust the oven thermostat-Do it yourselfBefore a Clean Cycle Using the self-cleaning ovenHow to Set the Oven for Cleaning After a Clean Cycle How to Delay the Start of CleaningControl Panel and Knobs Care and cleaning of the rangeSure Grip Handle Painted SurfacesOven Shelves Do not lift the door by the handle To clean the inside of the doorTo clean the outside of the door Lift-Off Oven DoorDo not remove any screws to remove the cover Oven Light ReplacementOven Heating Elements To remove the coverOperating Instructions Safety Information To replace a surface unit To remove a surface unitTo remove Cooktop Surface LightTo replace To replace the storage drawer How to Remove the Storage Drawer to Clean Under the RangeBroiler Pan & Grid To remove the storage drawerNational Parts Center Cleaning the glass cooktopDaily Cleaning For heavy, burned-on soilSpecial Care Wiring must conform to National Electric Codes Installation of the rangePrepare the Opening TipsPrepare for Electrical Connection Flooring Under the RangeBe installed before reinstalling the rear range wiring cover Power Cord Strain Relief InstallationDo not remove ground strap connection Wire Power Cord InstallationBefore After Wire Conduit Installation Screw Leveling the Range Anti-Tip Bracket InstallationFinal Check Before you call for service… Properly Control signals afterSurface units Not functioningBroil properly At Broil Broil HI/LO pad See the UsingOven will not work Food does notFood does not bake Oven temperatureClock and timer Is on when youOven not clean Self-cleanSelf-clean cycle When you wantedDisplay Power outageExcessive smoking Until the Locked DoorGeneral Electric Company Consumer Product Ownership Registration One Year GE Electric Range WarrantyFive Years Replacement glass cooktop if it should crack due We Will ReplaceIn-Home Repair Service 800-GE-CARES Service Telephone NumbersTDD 800-TDD-GEAC

164D3333P171, 49-8941 specifications

The GE 49-8941,164D3333P171 is an innovative component engineered for reliability and efficiency within various applications, mainly in the industrial and commercial sectors. Known for its robust design and advanced technology, this product underlines General Electric’s commitment to delivering high-quality solutions that cater to the demanding needs of professionals.

One of the standout features of the GE 49-8941 is its superior power handling capabilities. It is designed to meet stringent industry standards, ensuring that it can effectively manage higher electrical loads without compromising performance. This is particularly beneficial in heavy-duty applications where consistent power supply is crucial.

In terms of technology, the GE 49-8941 incorporates state-of-the-art circuitry which enhances its operational efficiency. This advanced circuitry minimizes energy losses during operation, translating into lower operational costs. Energy efficiency is a significant focus for modern industries, aligning with global initiatives for sustainability.

The component is also noted for its adaptability across various systems. Its design caters to a range of configurations, making it suitable for integration into existing systems without requiring extensive modifications. This flexibility enables businesses to upgrade their systems efficiently and effectively, ensuring that they remain competitive in an ever-evolving market.

Another characteristic of the GE 49-8941 is its durability. Built with high-quality materials, it is designed to withstand harsh environmental conditions, including temperature fluctuations and exposure to various chemicals. This resilience is vital for industries like manufacturing and energy, where equipment often faces challenging operational environments.

Moreover, safety features are paramount in the design of the GE 49-8941. It is equipped with advanced protective measures that prevent overloads and short circuits, which not only enhance the lifespan of the component but also contribute to the overall safety of the system in which it operates.

In summary, the GE 49-8941,164D3333P171 is a testament to General Electric’s engineering excellence. With its robust design, advanced technological features, energy efficiency, adaptability, and safety assurance, it stands out as a prime choice for industries seeking reliable and high-performing solutions.