~STALLATION ~STRUCTIONS
HOW TO CONVERT THE RANGE FOR USE
WITH 1P GAS OR HATURAL GAS (continued)
❑CONVERT TOP BURNER VALVES
1. Turn all top | \ | |
burners to LOW. | ||
| ||
2. Remove all | \ | |
four knobs. | ||
|
3. With a small flat W*\.‘ blade screwdriver, turn
the valve set screws
clockwise to decreasei flame size, counterclockwise \ //
to increase flame size. Adjust
%
until the flame is about the same[ height as the top of the burner.
4.Replace knobs.
5.Check for flame outage by opening and closing the oven door several times. If the flame goes out, increase the flame size.
❑CHECK QUALITY OF FL~ES
The combustion quality of burner flames needs to be determined visually.
If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use.
With LP gas, some yellow tipping on outer cones is normal.
m“’’’’’’’c~es-
(B) YeMow tips on outer cones—
Normal for LP gas
(C) %fi blue fl=eb
Normal for natural gas
48