Amana W10130752B installation instructions Complete Installation, If the flame needs adjusting

Page 11

If the flame needs adjusting:

1.Turn the oven off. Wait for the oven burner to cool down.

2.Open oven door and remove oven racks, oven tray, flame spreader and set aside.

A

A

B

C

A. Oven tray (lift up at area shown to remove)

B.Screws

C.Flame spreader

3.Locate the air shutter near the rear wall of oven and loosen the shutter screw.

A

B

A. Shutter screw

B. Air shutter

4.Adjust the air shutter.

5.Turn the oven back on and check for proper flame. If the flame is still not properly adjusted, turn the oven off, wait for the oven burner to cool down and repeat Step 4 until flame is properly adjusted.

6.When the flame has been properly adjusted, turn the oven off, wait for the burner to cool down.

7.Tighten the shutter screw.

8.Reinstall flame spreader and oven tray. Reinstall the oven racks and close oven door.

9.Close the oven door.

Complete Installation

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all of your tools.

3.Dispose of/recycle all packaging materials.

4.Check that the range is level. See “Level Range.”

5.Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material. Dry thoroughly with a soft cloth. For more information, see the “Range Care” section of the Use and Care Guide.

6.Read the Use and Care Guide.

7.Turn on surface burners and oven. See the Use and Care Guide for specific instruction on range operation.

If range does not operate, check the following:

Household fuse is intact and tight, or circuit breaker has not tripped.

Range is plugged into a grounded 3 prong outlet.

Electrical supply is connected.

See “Troubleshooting” in the Use and Care Guide.

8.When the range has been on for 5 minutes, check for heat. If the range is cold, turn off the range and check that the gas supply line shutoff valve is open.

If the gas supply line shutoff valve is closed, open it, then repeat the 5-minute test as outlined above.

If the gas supply line shutoff valve is open, turn to closed position and contact a qualified technician.

If you need Assistance or Service:

Please reference the “Assistance or Service” section of the Use and Care Guide or contact the dealer from whom you purchased your range.

11

Image 11
Contents Installation Instructions 30 76.2 CM Freestanding GAS Ranges Your safety and the safety of others are very important Range SafetyLocation Requirements Installation RequirementsTools and Parts Mobile home installations require Mobile Home Additional Installation RequirementsProduct Dimensions Cabinet Dimensions Natural gas Electrical RequirementsGas Supply Requirements Type of GasBurner Input Requirements Gas Supply Pressure TestingGas Supply Line Gas Pressure RegulatorUnpack Range Installation InstructionsInstall Anti-Tip Bracket Typical flexible connection Make Gas ConnectionTypical rigid pipe connection Complete Connection Verify Anti-Tip Bracket LocationLevel Range Check Operation of Cooktop Burners Initial lighting and gas flame adjustmentsIf the low flame needs adjusting Electronic Ignition SystemIf range does not operate, check the following Complete InstallationIf the flame needs adjusting If you need Assistance or ServiceTo Convert Gas Pressure Regulator GAS ConversionsLP Gas Conversion To Convert Oven Burner To Convert Surface BurnersNatural Gas Conversion Complete ConversionStd Burner W10130752B