3.Use a combination wrench and pliers to attach the flexible connector to the adapters. Check that connector is not kinked.
A
| B |
|
|
| D |
| C |
|
| E | F |
|
| G |
| H |
|
A. Pressure regulator | E. Adapter |
|
connection fitting | F. Use | |
B. Use | G. Manual shutoff valve | |
C. Adapter | H. ½" or ¾" gas pipe | |
D. Flexible connector |
|
|
Complete Connection
1.Locate gas pressure regulator in the broiler.
A
IMPORTANT: Do not remove the gas pressure regulator.
2.Check that the gas pressure regulator shutoff valve is in the “on” position.
5.Close the broiler door.
6.Remove cooktop burner caps and grates from parts package. Align notches in burner caps with pins in burner base. Burner caps should be level when properly positioned. If burner caps are not properly positioned, surface burners will not light. Place burners, burner caps and grates on the cooktop.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
7.Plug into a grounded 3 prong outlet.
Verify Anti-Tip Bracket Location
1.Check that the
■Look for the
■Slide the range back so the rear range foot is under the anti- tip bracket.
Front View | Front | Side View |
| ||
Shutoff valve |
| “ON” Position |
3.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
4.Test all connections by brushing on an approved noncorrosive
Level Range
1.Place rack in oven.
2.Place level on rack and check levelness of range, first side to side; then front to back.
3.If range is not level, pull range forward until rear leveling leg is removed from the
4.Push range back into position.
5.Check that rear leveling leg is engaged in
NOTE: Range must be level for satisfactory baking performance.