Amana W10130752B Gas Supply Line, Gas Pressure Regulator, Burner Input Requirements

Page 6

Gas Supply Line

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ½" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.

Flexible metal appliance connector:

If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, ½" (1.3 cm) or

¾" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:

Natural gas:

Minimum pressure: 5" WCP

Maximum pressure: 14" WCP

LP gas:

Minimum pressure: 11" WCP

Maximum pressure: 14" WCP

Contact local gas supplier if you are not sure about the inlet pressure.

A ½" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.

Do not kink or damage the flexible metal tubing when moving the range.

Rigid pipe connection:

The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection. All strains must be removed from the supply and fuel lines so range will be level and in line.

Must include a shutoff valve:

The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.

B

A

C

A. Gas supply line

B. Shutoff valve “open” position

C. To range

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Burner Input Requirements

Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level (not applicable for Canada).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least

1" water column pressure above the manifold pressure shown on the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

6

Image 6
Contents Installation Instructions 30 76.2 CM Freestanding GAS Ranges Range Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsLocation Requirements Mobile Home Additional Installation Requirements Product Dimensions Cabinet DimensionsMobile home installations require Type of Gas Electrical RequirementsGas Supply Requirements Natural gasGas Pressure Regulator Gas Supply Pressure TestingGas Supply Line Burner Input RequirementsInstallation Instructions Install Anti-Tip BracketUnpack Range Make Gas Connection Typical rigid pipe connectionTypical flexible connection Verify Anti-Tip Bracket Location Level RangeComplete Connection Electronic Ignition System Initial lighting and gas flame adjustmentsIf the low flame needs adjusting Check Operation of Cooktop BurnersIf you need Assistance or Service Complete InstallationIf the flame needs adjusting If range does not operate, check the followingGAS Conversions LP Gas ConversionTo Convert Gas Pressure Regulator To Convert Surface Burners To Convert Oven BurnerComplete Conversion Natural Gas ConversionStd Burner W10130752B