Roland GI-20 Selecting Patches, What is a Patch?, System Parameters and Patch Parameters

Page 12

Chapter 1 Try Playing Some Sounds

Level

String number

Sensitivity value

4.Play each string individually with the maximum force to be used during the actual performance, and as you play the string, adjust the sensitivity with [PATCH/ VALUE] until all five indicators light up momentarily.

Too low

All five indicators light up momentarily

5.When you have finished making the settings, turn the PARAMETER to return to “PLAY MODE.”

*Sensitivity is a system parameter. The settings are saved automatically when the memories (G1–G4) is changed or the PARAMETER knob is turned, even without the Write procedure being carried out. The settings in each of the memories (G1–G4) are applied to all patches. However, whichever of the sets G1–G4 to be used by each patch (Calling Up Input Sensitivity Settings” p. 18) is a patch parameter. Use the Write procedure to save these settings.

Selecting Patches

Switching the GI-20’s patches allows you to change the values of settings instantly and perform using a wide variety of sounds.

What is a Patch?

The various information used in performing with the GI-20 is stored in sets called “patches.” In each patch you can store the settings values for the parameters described below, and switching these patches allows you to reproduce their settings instantly.

 

 

 

 

 

 

Patch 50

 

 

 

• GUITAR SEL • BEND RANGE

 

 

 

 

Patch 03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Patch 02

STRING MUTE

 

 

 

 

 

 

 

 

Patch 01

 

MONO/POLY

 

 

 

 

 

 

 

 

• ASSIGN

 

 

• STRING MUTE

 

• PLAY FEEL

 

• TRANSPOSE

• GUITAR SEL

• BEND RANGE

 

 

 

 

 

• PRG CHANGE

• MONO/POLY

 

• ASSIGN

 

• STRING MUTE

• PLAY FEEL

• TRANSPOSE

 

 

 

 

• PRG CHANGE

• MONO/POLY

• ASSIGN

• STRING MUTE

 

 

 

• PRG CHANGE

• MONO/POLY

 

 

 

 

 

 

 

 

 

 

 

 

 

System Parameters and Patch Parameters

In contrast to the “patch parameters,” whose settings can be stored to each patch individually, parameters that are used by the GI-20 overall are called “system parameters.”

The following describes the different types of patch parameters and system parameters.

* Patch parameters are indicated in blue on the front panel.

System Parameters

SENSITIVITY (p. 11)

MIDI BASIC CH (p. 14)

MIDI CTL CH (p. 15)

PC MASK (p. 29)

MASTER TUNE (p. 28)

System parameters are stored in the GI-20 when you turn the PARAMETER knob after making changes to the settings.

*The MIDI BASIC CH and MIDI CTL CH parameters are also stored in the GI-20 when you press [SELECT] after making changes to the settings.

12

Image 12
Contents Main Features Using the Unit Safely page 2-3 and Important NotesPage For the U.K Power Supply PlacementMaintenance Additional PrecautionsContents Front Panel Rear Panel Signal Flow Installing the Divided Pickup on the Guitar or Bass Items to Have On HandAbout Midi Guitars That Cannot Be Used with the GK-2A/GK-2BConnection Examples Selecting the Guitar or BassPreparations to Make Before Performing Turning On the Power Adjusting the Input SensitivityTurning Off the Power Playing Sounds from a Sound ModuleWhat is a Patch? Selecting PatchesSystem Parameters and Patch Parameters System ParametersHow to Switch Patches When Not Switching PatchesAbout the Display Patch ParametersSetting the Midi Channel Setting the Transmission Mode MONO/POLYSetting the Midi Transmit Channel Basic CH When in Poly ModeSetting the Control Channel CTL CH Control ChangePress PATCH/VALUE to select the Basic channel number Performing on the Guitar Program ChangePress PATCH/VALUE to select the Control channel number Connecting to a Computer Setting the Midi PortSetting the Midi Data Path Signal Paths That Can Be Selected WithCalling Up the Input Sensitivity Settings Setting the Feeling of the Performance Play FeelSetting the Pedal and Switch Functions Assign Functions That Can Be Selected With Controller Function31, 64-95 Midi Control Change CC#1-31, CC#64-95 Pu Patch UpPd Patch Down Pt Patch Up/DownOu Octave Up Od Octave DownU4 Glide Up 4/d4 Glide Down U5-u8 Glide Up 5-8/d5-d8 Glide DownV1-V4 Vibrato B1 Pitch BendSetting the Range in Which Pitches Are Changed Bend Range Shifting the Pitch of the Sound TransposeSettings That Can Be Selected With Setting the Bend RangeSwitching Sounds on External Devices PRG Change Storing the Settings Write Muting Specific StringsPress Write Press PATCH/VALUE to select the save-destination patchConfirm that the GI-20 is set to Play Mode Copying PatchesPress PATCH/VALUE to select the copy-destination patch Convenient Functions Featured by the GI-20 Tuning TunerConvenient Functions Featured by the GI-20 OffReceiving Saved Data Using Midi Bulk Load Midi Turn the power off Receive Saved Data Through USB Bulk Load USBBend Data Thin Function Use a USB cable to connect the computer and the GI-20Reducing the Amount of Control Change Data Transmitted Limiting the Extent of the Bend Range Bend Range MAXReceive Control Change Data Thin Function Press PATCH/VALUE to select 12 orPress PATCH/VALUE to select SP or GE Turn the power off Selecting the Type of USB DriverReset to Default Factory Settings Factory Reset Installing the Rack Mount AdaptorTurn off the power to the GI-20 Attaching the Rubber FeetTroubleshooting Volume fluctuates from one string to anotherSound doesn’t vary when the settings are changed Pitch doesn’t change smoothlyProblems occur after switching GI-20 patches Pitch is wrong out of tune with the guitar/bassIs Midi Bend Range the same for both sending and receiving? Error Messages ReasonAction One-way Transfer Procedure Roland Exclusive MessagesData Format for Exclusive Messages Address-mapped Data TransferData set 1 DT1 12H Midi Implementation Channel Voice MessagesSystem Exclusive Message Control ChangeChannel Mode Message Appendices Transmit DataSystem Realtime Message Appendices Exclusive Communications Data Set 1 DT1 12HDecimal and Hexadecimal table Midi Implementation Chart Specifications GI-20 GK-MIDI InterfaceComputer GI-20Driver Installation With the GI-20 disconnected, start up WindowsOpen the System Properties dialog box Click the Hardware tab, and then click Driver SigningInstalling & Setting Up the Driver Windows Switch on the GI-20’s power switchPrepare the CD-ROM Connect the GI-20 to your computerIf What action do you want Windows to take? is set to Warn If What action do you want Windows to take? is set to BlockClick OK Click YesNext, you need to make the driver settings. p If you changed What action do you want Windows to take?Make sure that File signature verification is set to Ignore Fig.d13Fig.d16 Click Yes Continue the installation If File signature verification is set to WarnIf File signature verification is set to Block Restart Windows If you changed File signature verificationClick the Hardware tab, and then click Driver signature \Win98Me\Setupinf.exe SetupInf dialog box, click OK Settings Open Control PanelWindows XP Windows 98 users Open the Multimedia Properties dialog boxClick the Midi tab Set Midi outputInstalling the driver Use either OMS or FreeMIDI as the Midi driverSetting the driver Installing & Setting Up the Driver MacintoshVerify the Install Location, and click Install Click Restart to restart your MacintoshCreate a New Studio setup dialog box will appear. Click OK OMS Driver Search dialog box will appear. Click SearchMy Studio Setup Window, click the keyboard icon After you have finished the above check, exit OMS SetupAbout Quick Setup dialog box will appear. Click Continue Fig.d43Page Problems related to the USB driver Cannot install the driver correctlyGI-20 is not detected when making OMS or FreeMIDI settings Find new hardware wizard does not execute automaticallyTroubleshooting Does your computer meet the USB specifications?Deleting incorrect device information Can’t install/delete/use the driver in Windows XP/2000 Deleting the driverWindows XP/2000 users Did you make Driver Signing Options?Windows Me/98 users Macintosh usersIndex Index Tuner String SELAvis Information

GI-20 specifications

The Roland GI-20 is a groundbreaking MIDI guitar converter that allows electric guitarists to explore the vast world of MIDI technology. Designed to bridge the gap between traditional guitar playing and digital music production, the GI-20 transforms standard guitar signals into MIDI data, giving players access to a wide array of synthesized sounds and virtual instruments.

One of the main features of the GI-20 is its ability to track the guitar’s pitch with high accuracy. Utilizing Roland’s advanced technology, the device boasts rapid response times and minimal latency, ensuring that every note plucked or strummed is translated into MIDI in real-time. This precision is crucial for guitarists who wish to maintain their playing style while experimenting with synthesizers and sampled instruments.

In terms of connectivity, the Roland GI-20 is equipped with a 13-pin connector, allowing it to interface seamlessly with compatible Roland synths, sound modules, and other MIDI devices. Additionally, standard MIDI outputs enable connection to MIDI controllers and computers, providing an expansive toolkit for music creation.

The user interface is designed with simplicity in mind. A large LCD display allows for easy navigation of settings, while intuitive controls help players adjust parameters on the fly. Guitarists can also customize their performance by altering the sensitivity levels, enabling them to fine-tune how the device responds to their playing style.

The GI-20 offers an array of built-in sounds that mirror the capabilities of traditional synthesizers. These sounds can be layered or split into different tones based on the player’s preferences, offering a variety of sonic textures to enhance compositions. Furthermore, the ability to save and recall user settings allows for quick access to preferred configurations during live performances.

Another significant characteristic of the GI-20 is its compatibility with a wide range of guitars, including both electric and bass guitars. As long as the instrument is equipped with the appropriate pickup system, the GI-20 can effectively convert its output into MIDI signals.

In summary, the Roland GI-20 is a versatile and innovative tool for guitarists seeking to expand their creative horizons. With its accurate tracking, extensive connectivity, user-friendly interface, and a wealth of sounds, it unlocks the potential for guitarists to dive into the realms of electronic music and MIDI composition. Whether in the studio or on stage, the GI-20 opens up a world of possibilities for musicians looking to blend traditional guitar playing with modern technology.