Aga Ranges EC LM-2, EE LM-4 Electrical Connection, Instructions, Electrical Test Procedure

Page 7

ELECTRICAL CONNECTION

An electrical socket must be provided within 6 feet of the LH side of the appliance and easily accessible to the user to disconnect. Do not position socket above the appliance.

Electric Shock Hazard

Electrical Grounding is required on this appliance.

Do Not connect to the electrical supply until the appliance is permanently grounded. Disconnect the power to the junction box before making the electrical connection.

This appliance must be connected to a grounded, metallic, permanent supply or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.

Failure to follow these instructions could result in death or serious injury.

zA four-wire single phase 240-volt, 60-Hz, AC-only electrical supply is required on a separate, 30-amperes circuit, fused on both sides of the line. (See Fig. 2A - for wiring details).

zA time-delay fuse or circuit breaker is required.

zLocal codes permit the use of a U.L. listed, 250-volt, 30-amperes power cord. This cord contains four No.10 copper wires and matches a four-wire receptacle of type 14-50P.

Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the range (30-amperes).

zThe wiring diagram is located on the back of the L.H. door.

THIS APPLIANCE MUST HAVE THE FACILITY OF BEING COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY.

THE APPLIANCE MUST BE COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY BEFORE SERVICING.

WARNING

Electrical Grounding Instructions

This appliance is equipped with a grounding pin for your protection against a shock hazard and should be plugged directly

INSTRUCTIONS

Hand this Owners Manual to the user for retention and instruct in the safe operation of the appliance.

Also advise the user that, for continued efficient and safe operation of the appliance that servicing is carried out at intervals recommended by the Aga distributor.

ELECTRICAL TEST PROCEDURE

Final Electrical Test - Electric Voltage - Withstand Test

Procedure:

(Earth Appliance Test Simulation)

1.Select 1200 volts Flash Test on test equipment.

2.Plug in supply plug into the test equipment.

3.Depress the ‘Test Button’ for 1 second.

4.A ‘Pass’ light will illuminate.

5.If the appliance fails this test, re-check all circuits and correct the fault and retest the range.

6.Disconnect from the test equipment and connect range to its permanent supply.

7.A full load test will be performed using a clamp meter connected to the incoming supply. NOTE: The test results 10.5 -11 amps normal operation.

8.Make note of results and disconnect all leads.

7

Image 7
Contents For USE in USA/CANADA Comprising Installation & Users InstructionsContents Installation Section Range Base or Hearth InstallationInstallation Requirements General NotesEC-LM Model EE-LM Model Electrical Grounding Instructions Electrical Test ProcedureElectrical Connection InstructionsDesn Users Guide Child Safety Safety PrecautionsVentilating Hoods Where Applicable Basic Range Safety PrecautionsGrease Range AccessoriesRange Cooking Safety Precautions and Hints General Safety Precautions and Hints for cooking utensilsThermostat Control Heat IndicatorBeginning to cook on your Aga ServicingOperating Your AGA After your Aga has been assembledFitting of Oven Shelves Removal of Oven Shelves Moderate ROASTING/SIMMERING Oven Baking Oven Cleaning and Caring for Your AGADo not USE ANY Oven Cleaners High Roasting OvenPage Page Page Woodcrest Road Cherry Hill 800.633.9200