Broan E6036SS, E66136SS manual Install the Hood, Connect the Wiring ALL Blowers

Page 11
WALL ANCHORS LOCATION

13. INSTALL THE HOOD

CAUTION

 

Hold the hood until it is completely secured to the wood

 

mounting strip.

 

INTERNAL BLOWER(S) ONLY

MOUNTING SCREWS LOCATION

 

Run power cable to installation location. Remove the electrical compartment cover.

 

Insert the cable in the hood and tighten the wire clamp to secure the cable.

 

ALL INSTALLATIONS

HD0264

 

Rest the back cavity of the hood on the wood mounting strip.

Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4’’ (for 30’’ and

36’’ width hoods) or (6) screws (for 42’’ and 48’’ width hoods) provided at locations shown. Drill (3) 3/16’’ size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the three wall anchors with the remaining no. 8 x 3/4’’ screws and the (3) washers provided.

For a non-ducted installation, go to step 15, Connect the wiring.

14.ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY)

Run power cable to installation location. For ducting through top of hood, existing plate remains in place on inside back of hood.

For ducting through back of hood, remove existing plate from inside back of hood and remove the rough-in plate from the top of hood. Attach the plate to inside top of hood to cover hole. Secure to threaded studs with same (4) nuts. Install the rough-in plate to the back of hood so that the wiring box is located on the right side as you are facing the hood.

Connect ducting to rough-in plate as you are installing the rough-in plate. Use duct tape to make all joints secure and air-tight.

ROUGH-IN PLATE

ON TOP OF HOOD

WIRING

LOCKNUTS

COVER

LOCKNUTS

HD0262 PLATE ON BACK OF HOOD

15. CONNECT THE WIRING (ALL BLOWERS)

!WARNING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally.

Remove wiring cover from rough-in plate or electrical compartment and set aside.

INTERNAL BLOWERS: Connect cable into wiring box using wire connectors. Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.

CAUTION

The ORANGE wire (A) is for make-up air device connection only. If there is no make-up air device, never remove the cap on the ORANGE wire end.

Reinstall wiring cover.

IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.

A

HE0088

- 11 -

Image 11
Contents Intended for Domestic Cooking only Installation InstructionsTo Reduce the Risk of a Range TOP Grease Fire Backsplash E60000 Series HoodRMP Series Or 332H 900 CFM Odel HLB9 800 CFMOr HLB11 1100 CFM Odel 331H 600 CFM Odel 335 1200 CFMDucted Installation Select Blower Option and Installation TypeNON-DUCTED Installation Prepare the Installation Measure Installation10¼ 10½ Prepare the Installation CONT’DInstall Backsplash Optional 918 Remove the Adapter Internal Blower Hoods only Remove Filters and the Grease Drip Rail Choose the Openings Internal Blowers Hood only Horizontal Discharge Installation Internal Blowers Hood only Ducted Installation only Install the Adapter and the Transition if Need beInstall Wood Mounting Strip Install AEE Optional Soffit ChimneyROUGH-IN Plate Location External Blowers Hoods only Install the HoodConnect the Wiring ALL Blowers Install the Blower Exterior or IN-LINE Blower Reinstall Grease Drip Rail and Baffle FiltersInstall Light Bulbs Heat Sentry USE and CareOperation Blower WarrantyONE Year Limited Warranty for Broan Elite Products Cooktop Lighting HalogenExterior or In-Line blower hoods Wiring DiagramsBroan Elite E60000 Series Internal blowers hoodsBroan Elite E60000 Series Exterior or In-Line blower hoods Service PartsBroan Elite E60000 Series Internal blower hoods Conçue Uniquement Pour LA Cuisson Domestique Guide D’INSTALLATIONAfin DE Réduire LES Risques DE FEU DE Cuisinière AvertissementSérie RMP Hotte Série E60000Dosseret OU 332H 900 PCM Dosseret Série RMPOU HLB11 1100 PCM Installation Avec Conduits Sélectionner L’OPTION Ventilateur ET LE Type D’INSTALLATIONInstallation EN Recirculation Préparer L’INSTALLATION Mesurer L’INSTALLATIONInstaller LE Dosseret Optionnel Préparer L’INSTALLATION SuiteRetirer LES Filtres ET LA Gouttière Hotte À Ventilateurs Intérieurs Seulement Installation À Évacuation HorizontaleInstaller LA Cheminée Décorative Optionnelle DE Série AEE Installer L’ADAPTATEUR ET LA Transition LE CAS ÉchéantInstaller LA Lisière DE Bois Installer LE KIT DE Recirculation DE Série ANKE60Hottes À Ventilateur Externe Seulement Installer LA HotteEmplacement DE LA Plaque Ventilateur Branchement Électrique Tous LES VentilateursRemettre EN Place LA Gouttière ET LES Filtres À Chicane Installer LE Ventilateur Extérieur OU EN LigneInstaller LES Ampoules Heat Sentrymc EntretienFonctionnement Garantie Limitée DE UN AN DES Produits Broan Elite GarantieÉclairage DE LA Surface DE Cuisson Halogène VentilateurHottes à ventilateur extérieur ou en ligne Schémas ÉlectriquesBroan Elite Série E60000 Hottes à ventilateurs intérieursVIS N 8 X 3/8 PO VIS N 8 X 3/4 PO 23. Pièces DE RechangeBroan Elite Série E60000 Hotte à ventilateurs Intérieurs Exclusivamente Para Cocinas Domésticas Instrucciones DE InstalaciónPrecaución Advertencia¼ X 10 a Campana DE LA Serie E60000Serie RMP Placa Posterior Modelo 634 O12 a Modelo 331H HLB9 800 PCM O HLB11 1100 PCMModelo 335 1200 PCM 336 1500 PCMInstalación CON Tubos Instalación SIN TubosPreparación DE LA Instalación MedidasSerie RMP opcional Preparación DE LA Instalación ContinuaciónInstalación DE LA Placa Posterior Opcional Nota Sólo para las instalaciones con tubos Desmontaje DEL AdaptadorDesmontaje DE LOS Filtros Y DEL Riel DE Vertido DE LA Grasa Campanas CON Ventilador Interior ÚnicamenteVentiladores Interiores Únicamente Instalación DE LA Evacuación HorizontalInstalación SIN Tubos Únicamente Instalación DEL Adaptador Y DEL Cambio DE SecciónInstalación DEL Conjunto DE Recirculación Anke Instalación DE LA Regleta DE MontajeConexión DEL Cableado Todos LOS Ventiladores Ubicación DE LA Placa DEL VentiladorInstalación DE LA Campana Campanas CON Ventiladores Exteriores ÚnicamenteInstalación DE LAS Bombillas Instalación DEL Ventilador Exterior O EN LíneaTermostato Heat Sentry Utilización Y CuidadoFuncionamiento Garantía Limitada DE UN AÑO DE LOS Productos Broan Elite GarantíaIluminación DE LA Superficie DE Cocción Luces Halógenas VentiladorCampanas con ventilador exterior o en línea Campanas con ventilador interiorDe la serie E60000 de Broan Elite Tornillos N X 3/8 PiezasFiltros 8.84 X Filtros 11.84 X