gas connection
Explosion Hazard
Use a new CSA or UL approved gas supply line.
Install a
Securely tighten all gas connec- tions.
If connected to LP, have a quali- fied person make sure gas pres- sure does not exceed 14" water column.
Examples of a qualified person include licensed heating per- sonnel, authorized gas compa- ny personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Propane gas.
The cooktop is equipped for the use with NATURAL gas. It is
The model/serial rating plate, located on the underside of the burner box, has information on the type of gas that can be used. If this information does not agree with the type of gas available, check with the local gas supplier. See page 16 for L.P. gas conversion instructions.
1. Manual Shut-off Valve (fig. 5.1):
A manual
Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.
Shutoff valve
“open” position
To cooktop
Gas supply line
Fig. 5.1
2.Pressure Regulator (figures 5.2a - 5.2b - 5.2c - 5.2d):
a)All heavy duty, commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation, since service pressure may fluctuate with local demand. The regulator supplied with this cooktop must be installed before any gas connections are made.
Use supplied pressure regulator only.
12