b)Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company. Please provide the service person with this manual before work is started on the cooktop. (Gas conversions are the responsibility of the dealer or end user.)

c)This cooktop can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory adjusted for use with NATURAL gas.

d)Manifold pressure should be checked with a manometer; NATURAL gas requires 4.0” W.C.P. and LP/PROPANE requires 11.0” W.C.P (see figure 5.4).

Incoming line pressure upstream from the regulator must be 1” W.C.P. higher than the manifold pressure in order to check the regulator.

The regulator used on this cooktop can withstand a maximum input pressure of 1/2 PSI (14.0” W.C.P). If the line pressure is in excess of that amount, a step- down regulator will be required.

 

To cooktop

Screw

Manifold

 

 

test point

 

pressure

 

1/8” NPT

Unscrew

 

 

To mains

 

connection

 

Fig. 5.4

e)The appliance, its individual shut-off valve, and pressure regulator must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 PSI (3.5 kPa).

f)The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa).

3. Flexible Connections:

If local codes permit, CSA design-certified, flexible metal appliance connector is recommended for connecting this cooktop to the gas supply line. Do Not kink or damage the flexible connector when moving the cooktop. The pressure regulator has 3/8" NPT female pipe threads.You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve.

15

Image 15
Contents Model VEGCT424F Dear Customer Tips for the User Important Precautions and RecommendationsCooking Points FeaturesUsing the gas cooktop GAS BurnersChoice of Burner fig Cleaning and maintenance Correct Position of Triple Ring Burner Correct Replacement of the BurnersTools Needed for Installation Installation InstructionsElectrical Grounding Instructions Replacement PartsCooktop Dimensions Installation to the cabinetFastening the Cooktop .3 Proximity to Side CabinetsGas connection Explosion HazardManual Shut-off Valve fig Pressure Regulator Installation Step Gasket GAS Connection SpecificationScrew Manifold Test point Pressure NPT Unscrew Flexible ConnectionsConversion to LP/PROPANE GAS Leak TestingSetting the Pressure Regulator fig Rigid Pipe ConnectionsOperations to be Performed When Substituting the Injectors Regulating the Burner Minimum SettingInjectors Table Recommended ground method Electrical connectionWiring diagram key Wiring Diagram Caca CA CACod -ß1