Verona VEGCT424F warranty Electrical Grounding Instructions, Replacement Parts

Page 9

GENERAL INFORMATION

1.Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Latest Edition.

2.Installation in manufactured (mobile) home: installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or with local codes where applicable.

3.Installation in Recreational Park Trailers: installation must conform with state or other codes or, in the absence of such codes, with the Standard for Recreational Park Trailers, ANSI A119.5.

4.WARNING: This appliance shall not be used for space heating. This information is based on safety considerations.

5.AlI openings in the wall behind the appliance and in the floor under the appliance shall be sealed.

6.Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.

7.Do not obstruct the flow of combustion and ventilation air.

8.Disconnect the electrical supply to the appliance before servicing.

9.When removing appliance for cleaning and/or service;

A.Shut off gas at main supply.

B.Disconnect AC power supply.

C.Disconnect gas line to the inlet pipe.

D.Carefully lift appliance out of cabinet cutout. CAUTION: Use care in handling.

10.Electrical Requirement

Electrical installation should comply with national and local codes.

11.Air Supply and Ventilation

The installer must refers to local/national codes.

12.Gas Manifold Pressure

Natural gas - 4.0” W.C.P. LP/Propane - 11.0” W.C.P.

WARNING!!

ELECTRICAL GROUNDING INSTRUCTIONS

The cooktop must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70-latest edition. Installation should be made by a Iicensed electrician.

This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded socket. Do not cut or remove the grounding prong from the plug.

For personal safety, this appliance must be properly grounded.

Do not under any circumstances cut or remove the third (ground) prong from the power plug.

REPLACEMENT PARTS

Only authorized replacement parts may be used in performing service on the cooktop. Replacement parts are available from factory authorized parts distributors. Contact the nearest parts distributor in your area.

9

Image 9
Contents Model VEGCT424F Dear Customer Tips for the User Important Precautions and RecommendationsCooking Points FeaturesUsing the gas cooktop GAS BurnersChoice of Burner fig Cleaning and maintenance Correct Position of Triple Ring Burner Correct Replacement of the BurnersTools Needed for Installation Installation InstructionsElectrical Grounding Instructions Replacement PartsCooktop Dimensions Installation to the cabinetFastening the Cooktop .3 Proximity to Side CabinetsGas connection Explosion HazardManual Shut-off Valve fig Pressure Regulator Installation Step Gasket GAS Connection SpecificationScrew Manifold Test point Pressure NPT Unscrew Flexible ConnectionsSetting the Pressure Regulator fig Leak TestingRigid Pipe Connections Conversion to LP/PROPANE GASOperations to be Performed When Substituting the Injectors Regulating the Burner Minimum SettingInjectors Table Recommended ground method Electrical connectionWiring diagram key Wiring Diagram Caca CA CACod -ß1