SECTION 2 – INSTALLATION

WARNING – After any conversions, readjustments, or service work on the oven:

Perform a gas leak test.

Test for correct air supply, particularly to the burner blower.

Test for proper combustion and gas supply.

Check that the ventilation system is in operation.

WARNING - Keep the appliance area free and clear of combustibles.

WARNING – The oven must be installed on an even (level) non-flammable flooring and any adjacent walls must be non-flammable. Recommended minimum clearances are specified in the Description section of this manual.

WARNING – Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no obstructions around or underneath the oven. Constructional changes to the area where the oven is installed shall not affect the air supply to the oven.

CAUTION: To reduce the risk of fire, the appliance is to be mounted on floors of noncombustible construction with noncombustible flooring and surface finish and with no combustible material against the underside thereof, or on noncombustible slabs or arches having no combustible material against the underside thereof, such construction shall in all cases extend not less than 12 inches (304mm) beyond the equipment on all sides.

CAUTION: For additional installation information, contact your local Authorized Service Agent.

NOTE – There must be adequate clearance between the oven and combustible construction. Clearance must also be provided for servicing and for proper operation.

NOTE – An electrical wiring diagram for the oven is located inside the machinery compartment.

NOTE: All aspects of the oven installation, including placement, utility connections, and ventilation requirements, must conform with any applicable local, national, or international codes. These codes supersede the requirements and guidelines provided in this manual.

NOTE: In the USA, the oven installation must conform to local codes. In the absence of local codes, gas oven installations must conform with the National Fuel Gas Code, ANSI Z223.1. Gas and electric ovens, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code (NEC), or ANSI/NFPA70.

NOTE: In Canada, the oven installation must conform with local codes. In the absence of local codes, gas oven installations must conform with the Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Gas Installation Code, CAN/CGA-B149.2, as applicable. Gas and electric ovens, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the Canadian Electrical Code CSA C22.2.

3

Image 7
Contents Owners Operating and Installation Manual Retain this Manual for Future Reference Middleby Marshall Table of Contents Description Voltage Draw DimensionsGeneral Specifications Recommended Minimum ClearancesInstallation PS640 Oven Installation Required Kits and Equipment Model PS640 Single Oven Option Base with Legs and Top Model PS640 Double Oven Option Base with Legs and Top Model PS640 Triple Oven Option Base with Outriggers and Top Lead to Increased Service Expenses for the Owner IV. Assembly 10. Top panel installation Do not Overtighten the Conveyor Belt Conveyor InstallationReversing the Conveyor Belt Resetting Direction JumperSwitching Photo Detector Conveyor Belt ReversalVII. GAS Supply ConnectionPS640 Propane Conversion Adjusting the Maximum Pressure SettingConnection Gas ConversionMaintenance Adjusting the Minimum Pressure SettingCheckout Location and Description of Controls Main Screen Normal Operation STEP-BY-STEPQuick Reference Touch Screen Controller Main Screen Daily Startup ProcedureDaily Shutdown Procedure Oven Temperature/Set Point/Indicator ScreenIII. Quick Reference Troubleshooting Maintenance Daily MaintenanceTop Row Bottom Row II. Maintenance MonthlySplit Belt Disassembly and Cleaning III. Maintenance Every 3 MonthsBlower Belt IV. Maintenance Every 6 MonthsKEY Spare Parts Available separately. See Figure KEY Spare Parts PS640 GAS B & W TouchscreenWiring Diagram Page