Sharp MMD24B, MMD24S DESCRIPTION OF LSI IC-1, Pin No, Description, Power source voltage 0V GND

Page 20
DESCRIPTION OF LSI (IC-1)

MMD24S

MMD24B

 

 

 

DESCRIPTION OF LSI (IC-1)

The I/O signal of the LSIis detailed in the following table.

 

 

 

 

Pin No.

Signal

I/O

Description

 

 

 

 

1 - 3

AN5- AN3

IN

Terminal to change cooking input according to the Model.

 

 

 

By using A/D converter contained in the LSI, DC voltage in accordance with the Model

 

 

 

in operation is applied to set up its cooking constant.

 

 

 

 

4

AN2

IN

Input signal which inform the drawer door is in the middle position between the opened

 

 

 

position and the closed position, to LSI from the door position switch rear.

 

 

 

 

5

AN1

IN

Terminal not used.

 

 

 

 

6

AN0

IN

Terminal not used.

 

 

 

 

7

CNVSS

IN

Power source voltage: 0V (GND).

 

 

 

VC voltage of power source circuit input. Connected GND.

 

 

 

 

8

RESET

IN

Auto clear terminal.

 

 

 

Signal is input to reset the LSI to the initial state when power is applied. Temporarily set

 

 

 

to “L” level the moment power is applied, at this time the LSI is reset. Thereafter set at

 

 

 

“H” level.

 

 

 

 

9

P62

OUT

Terminal not used.

 

 

 

 

10

P61

IN/OUT

Terminal not used.

 

 

 

 

11

VSS

IN

Power source voltage: 0V (GND).

 

 

 

VS voltage of power source circuit input. Connected GND.

 

 

 

 

12

XIN

IN

Internal clock oscillation frequency setting input.

 

 

 

The internal clock frequency is set by inserting the ceramic filter oscillation circuit with

 

 

 

respect to Xout terminal.

 

 

 

 

3

XOUT

OUT

Internal clock oscillation frequency control output.

 

 

 

Output to control oscillation input of Xin.

 

 

 

 

14

VCC

IN

Power source voltage: +5V.

 

 

 

VC voltage of power source circuit input.

 

 

 

 

15

P60

IN

Plus signal coming from the Microwave drawer door open-close motor is input into P60

 

 

 

as revolution number.

 

 

 

 

6

P37

IN

Input signal which communicates the drawer door open information to LSI from

 

 

 

the door position switch front.

 

 

 

Door opened; “L” level signal(0V).

 

 

 

Door closed; “H” level signal(+5V).

 

 

 

 

17

P36

OUT

Signal to change the rotational direction is output to the Microwave drawer door

 

 

 

open-close motor.

8

TXOUT

OUT

Signal to change the rotational speed is output to the Microwave drawer door open-close

 

 

 

motor.

 

 

 

 

9

P34

OUT

Power source to drive the Microwave drawer door open-close motor is output.

 

 

 

 

20

RXD2

IN

Input terminal to check the data of display.

 

 

 

Data signal from IC-2 is input to RXD2 to check the flow of the data.

 

 

 

 

21

TXD2

IN

Output terminal to send IC-2 the data.

 

 

 

The data of display is output to IC-2.

 

 

 

 

22

SCLK2

OUT

Clock timing signaI output terminal.

 

 

 

Clock timing signal is sent to IC-2.

 

 

 

 

23

P30

OUT

Signal to reset LSI.

 

 

 

Signal is output to reset IC-2.

 

 

 

 

24 - 25

COM3 - COM2

OUT

Terminal not used.

 

 

 

 

26

COM1

OUT

Common data signal.

 

 

 

Connected to LCD signal C5.

 

 

 

 

20

Image 20
Contents TABLE OF CONTENTS WARNING TO SERVICE PERSONNELWARNING TO SERVICE PERSONNEL MICROWAVE MEASUREMENT PROCEDUREBEFORE SERVICING WARNING TO SERVICE PERSONNEL After repairingBefore Servicing When the testing is completedMICROWAVE MEASUREMENT PROCEDURE B. Preparation for testingA. Requirements C. Leakage testDANGER 1440 Bridge Gate Dr Diamond Bar, CASERVICE MANUAL If provided, Vent Hood, Fan assembly, Cooling Fan MotorMICROWAVE DRAWER SPECIFICATION DESCRIPTIONGENERAL INFORMATION GROUNDING INSTRUCTIONSPOWER LEVEL P-0 TO P-90 COOKING OPERATIONDESCRIPTION OF OPERATING SEQUENCE OFF CONDITIONMICROWAVE SENSOR COOKING CONDITIONCooking Sequence DOOR SCHEMATIC OFF CONDITIONCLOSED, COOK OFF CONDITTION TEST PROCEDURES PROCEDUREA TOUCH CONTROL PANEL ASSEMBLY TEST Before testingC RELAY TEST COMPONENT TESTB KEY UNIT TEST Check supply voltage and oven power cord DEFROST TESTSTEPS The rated AC voltage is not present betweenWater load cooking test TESTING METHOD FOR AH SENSOR AND/OR CONTROL UNITF AH SENSOR TEST Checking the initial sensor cooking condition CHECKING CONTROL UNIT R1, R2 22Ω ± 1% 1/2W R3 4.3kΩ ± 5% 1/4W R4 1MΩ ± 5% 1/4WRefer to the disassembly instructions found on Page G MAGNETRON ASSEMBLY TESTMICROWAVE OUTPUT POWER H THERMAL CUT-OUT TESTK MONITOR SWITCH TEST I SECONDARY INTERLOCK SWITCH TESTJ STOP SWITCH TEST M POWER TRANSFORMER TEST L BLOWN MONITOR FUSE TESTTOUCH CONTROL PANEL ASSEMBLY Control Unit and Power Unit4 Reset Circuit 5 Indicator CircuitDESCRIPTION OF LSI IC-1 Power source voltage 0V GNDInternal clock oscillation frequency setting input Power source voltage +5VSignal Segment data signalSignal coming from touch key Signal similar to P23Magnetron high-voltage circuit driving signal Common relay driving signal. Square Waveform 60HzSignal to sound buzzer Signal to synchronize LSI with commercial power source frequencyHUMIDITY SENSOR CIRCUIT ventilation opening for sensing1 Structure of Humidity Sensor 2 Operational Principle of Humidity SensorTOUCH CONTROL PANEL SERVICING 1 Servicing the touch control panel with power supply of the oven4. Other Precautions 2. Servicing of Touch Control PanelPRECAUTIONS FOR USING LEAD-FREE SOLDER 2. Using lead-free wire solder1. Employing lead-free solder 3. SolderingCOMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE WARNING FOR WIRINGWARNING AGAINST HIGH VOLTAGE To prevent an electric shock, take the following pre- cautionsMICROWAVE DRAWER DISASSEMBLY POWER CORD REPLACEMENT Un-hook/Attach Black AC Wire to Top TerminalUn-hook/Attach White AC Wire to Bottom Terminal Un-hook/Attach Ground to metal Tab on Back PlateSTOP SWITCH, SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH REMOVAL STOP SWITCH, SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH ADJUSTMENTRe-install After adjustment, check the followingDRAWER ASSEMBLY AND CHOKE REMOVAL DRAWER SUPPORT ANGLE REMOVALDRAWER/SLIDE RAIL REMOVAL 1. Follow the Microwave Drawer disassembly as previouslySWITCH ANGLE REMOVAL/ADJUSTMENT SWITCH ANGLE REMOVALACTUATOR REMOVAL/ADJUSTMENT Actuator adjustmentAUTO DRAWER GEAR REMOVAL/INSTALLATION Bottom coverRACK GEAR REMOVAL InstallationHIGH VOLTAGE COMPONENTS to Back PlateFigure S-2. Power Unit Circuit MICROFM A CN-AUNIT CONTROLUNIT F G HA B C D E F G H Figure S-4. Printed Wiring Board of Power Unit2.5A 5.PrintedWiringBoard UnitControlofCOPYRIGHT 2008 BY DACOR, INC ALL RIGHTS RESERVED