CMA Dishmachines CMA-180 manual Wire Colors Circuit Voltage Function

Page 7

flexibility to permit the machine to be moved for cleaning without having to disconnect any wiring.

ii.Run your dispenser wires through the conduit to the control box.

iii.Run your probe wires to the control box.

iv.With the machine’s power “OFF”, connect your detergent and rinse dispenser wires to the red and blue terminals of the power block supplied inside the control box. The table that follows lists the function of each conductor of the multi- conductor electrical cable.

Wire Colors

Circuit Voltage

Function

Gray/Violet

200 VAC-249 VAC 50/60 Hz

Main AC Power

Brown

200 VAC-249 VAC 50/60 Hz

Main AC Power

Black

No Connection. Insulate this wire!

This wire is LIVE!

Yellow

24 VAC-240 VAC 50/60 Hz

Detergent Signal

White/Yellow

24 VAC-240 VAC 50/60 Hz

Detergent Signal

Violet

24 VAC-240 VAC 50/60 Hz

Rinse Signal

White/Violet

24 VAC-240 VAC 50/60 Hz

Rinse Signal

The individual conductors need to be connected as shown on the wire diagram below. Probe wires are to be striped, crimped on barrel male and female connectors provided, and connected to the pre-wired violet wires in the control box.

MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03

Page 6

Image 7
Contents Model CMA-180 Table of Contents CMA-180/CMA-180T SpecificationsShipping Weight Introduction to CMA-180 Getting StartedPlumbing ElectricalNova Detergent and Rinse Dispenser Wire Colors Circuit Voltage Function Model CMA-180 Installation & Operation Rev Exhaust Fan Control Water Tempering Kit Installation Checklist Machine Start-Up Procedures Electrical Requirements Single Phase Rinse Booster Heater Wash Tank HeaterPhase and 1 Phase Wiring Options Wiring OptionsSolution Quick service guideInitial Parts KIT P/N Auto-Fill Solid State Timer Wire Diagram Wire Diagram for CMA-180 Booster Only