4. Quick service guide
MODEL: CMA 180 HIGH TEMP |
|
|
TECHNICAL ISSUE | CAUSE | SOLUTION |
Door magnetic reed switch problem | Faulty magnetic reed switch | Check wire connections inside control box |
|
|
|
|
| Contact factory for new retrofit, corner P/N |
|
| 00566.10 straight P/N 00566.20 |
Door mechanical switch problem | Switch alignment issue | Align switch |
|
|
|
| Switch button broke | Replace switch, P/N00562.00 |
|
|
|
| Delimer switch is in OFF position | Flip to NORMAL position |
|
|
|
| Loose wire connections | Check and crimp connectors |
|
|
|
Pump motor not running | Faulty # 3 micro switch in cam timer | Replace micro switch, P/N 00411.00 |
|
|
|
| Faulty contactor | Replace contactor, P/N 00404.85 |
|
|
|
| Faulty wash pump motor | Replace wash pump motor, P/N 00201.00 |
|
|
|
| Faulty # 3 micro switch in cam timer | Replace micro switch, P/N 00411.00 |
|
|
|
Pump motor runs continuous | Delimer switch is in DELIME position | Flip to NORMAL position |
|
|
|
| Faulty contactor | Replace contactor, P/N 00404.85 |
|
|
|
| Booster heater thermostat not properly set | Adjust thermostat |
|
|
|
| Incoming main water temperature below 140 F | Raise water temperature to 140 F |
Final rinse water below 180 degree F |
|
|
| Tripped or faulty high limit switch | Reset or replace high limit switch, P/N 17523.51 |
| Faulty contactor | Replace contactor, P/N 13003.17 |
| Faulty booster heater element | Replace heating element, P/N 13417.67 |
| Scaled heating element | De- scale heating element |
| Thermostat is not properly adjusted | Adjust thermostat |
|
|
|
| Loose lead connection | Check connectors and secure |
Wash tank heater is not operational | Tripped or faulty high limit switch | Reset or replace high limit switch, P/N 17523.51 |
|
|
|
| Faulty float switch | Replace float switch, P/N 13463.00 |
| Faulty contactor | Replace contactor, P/N13003.50 |
| Faulty heating element | Replace heating element, P/N 13417.65 |
| Water regulator not adjusted properly | Adjust regulator to |
| Clogged final rinse spray jets | Clean jets |
Low water pressure at the final rinse | Missing final rinse spray end cap | Replace end cap, P/N 00308.17 |
|
|
|
| Low incoming water pressure from building | Increase pressure |
|
| |
Water solenoid leaks | Scaled or dirty solenoid valve | Clean valve |
|
|
|
| Faulty solenoid valve diaphragm | Replace diaphragm, P/N 00706.00 |
| Thermostat not properly set | Adjust thermostat |
|
|
|
Wash water temperature too low/high | Scaled heating element | Clean scale, delime machine |
|
|
|
| Faulty temperature gauge | Replace gauge, P/N 03202.00 |
| Position or proper operation of door switch | Adjust or replace door switch, P/N 00557.55 |
|
|
|
| Delimer switch is on OFF position | Flip to NORMAL position |
Machine does not operate when the door is | Faulty 1st micro switch in cam timer | Replace micro switch, P/N 00411.00 |
|
| |
|
| |
closed | Check cam timer motor | Replace timer if needed, P/N 00409.17 |
| Check ice cube relay | Replace if faulty, P/N 00631.05 |
| Faulty wash pump contactor | Replace contactor, P/N 00404.85 |
|
| |
MODEL | Page 14 |