CMA Dishmachines manual Model CMA-180 Installation & Operation Rev

Page 8

2.Remove the plug from the mixing chamber located by the vacuum breaker on the back of machine; and install the rinse injection fitting (supplied with your dispenser).

3.A 7/8” detergent injection hole is provided in the back of the wash tank. Remove the S.S. plug and install the detergent fitting (supplied with your dispenser).

4.A 7/8” chemical probe hole is provided in the front of the wash tank heater just below hi limit switch. Insert the probe into the hole from inside the wash tank and secure it with the probe retaining nut provided. Connect ring connectors to the probe with nuts and star washers provided.

5.The final step of installing the CMA supplied Detergent and Rinse Dispenser is programming it to your specific application. The reference manual supplied with the dispenser shows you how to program it.

Keep in mind while reading the reference manual that the CMA-180 operates in “probe” mode. (This mode is selected by setting a value of “1” in screen 21).

Screen 22 must be set to “1” (Door).

There are four user functions with this dispenser. Their operation is described in the reference manual.

MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03

Page 7

Image 8
Contents Model CMA-180 Table of Contents Specifications CMA-180/CMA-180TShipping Weight Getting Started Introduction to CMA-180Nova Detergent and Rinse Dispenser ElectricalPlumbing Wire Colors Circuit Voltage Function Model CMA-180 Installation & Operation Rev Exhaust Fan Control Water Tempering Kit Installation Checklist Machine Start-Up Procedures Single Phase Rinse Booster Heater Wash Tank Heater Electrical RequirementsWiring Options Phase and 1 Phase Wiring OptionsQuick service guide SolutionInitial Parts KIT P/N Auto-Fill Solid State Timer Wire Diagram Wire Diagram for CMA-180 Booster Only