Vanguard Heating SBVRBN Installation of Listed B-1 Vent, Installing Vent System in a Chase

Page 10

® SBVRBN AND SBVRBP

CAST IRON STOVE AND BURNER SYSTEM

VENTING INSTALLATION

Continued

INSTALLATION OF LISTED B-1 VENT

WARNING: Installation should only be made by qualified per- sons who are familiar with the safety procedures required for the installation of the product, who are equipped with the proper tools and testing instruments, and who have achieved proper certification of licensing. Instal- lations made by unqualified per- sons can result in the risk of in- jury or electrical shock which can be serious or even fatal.

Figures 22 through 24 show other options for the gas vent. When venting through a side wall your vent pipe must have the proper temperature rating (see Figure 24). Manufacturer's clearances must also be maintained. Consult the authority having jurisdiction in your area regarding venting through side wall.

Figure 22 - Vertical Venting Through Ceiling Using Two 90º Elbows

Figure 23 - Vertical Venting Configuration Through Chimney

Figure 24 - Venting Through a Side Wall

INSTALLING VENT SYSTEM IN A CHASE

A chase is a vertical box-like structure built to enclose venting that runs along the out- side of a building. A chase is not required for such venting.

NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the re- quirements of local building codes. You must follow all local building codes.

Note: When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially im- portant in cold climates. Minimum clear- ance between vent pipes and combustible materials such as insulation is 1".

CHECKING VENT CAPACITY

Complete all gas piping, electrical, and vent connections. After adjusting the burner sys- tem and lighting the main burners, allow a couple of minutes for warm-up. Hold a lighted match just under the rim of the draft hood relief opening. Proper venting will draw the flame toward or into the draft hood. Improper venting, indicated by escape or spillage of burned gas, will cause match to flicker or go out. Smoke from a cigarette will also be pulled into the draft hood if the vent is drawing properly.

Figure 25 - Test for Proper Venting

For more information, visit www.desatech.com

10

106707

Image 10
Contents For Your Safety For Your Safety What to do if YOU Smell GASSafety Information Sbvrbn and Sbvrbp Cast Iron Stove and Burner SystemLocal Codes Product FeaturesProduct Identification OperationPRE-INSTALLATION Preparation Location and Space RequirementsCast Iron Stove and B-VENT Burner System Assembly Stove Body AssemblyAttaching Stove Legs Installing B-VENT Burner System Into Stove Body Installing Optional Blower AccessoryCast Iron Stove and DIRECT-VENT Burner System Assembly Installing Rear CoverInstallation Precautions Venting InstallationType B-VENT Installation Listed B-0 or Greater Installing Vent System in a Chase Installation of Listed B-1 VentChecking Vent Capacity Chimneys High Altitude InstallationRelining Systems Troubleshooting Venting Problems Cast Iron Stove and B-VENT Burner System InstallationInstallation Items Needed Tion. Purchase the CSA/AGA design-certiPressure Testing Burner System Gas Connections Connecting STOVE/ Burner System to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Installing Remote Receiver Thermostat Base Terminal W and RInstalling 9-Volt Battery in Hand- Held Remote Control Unit REMOVING/REPLACING Glass DoorInstalling LOGS, Lava ROCK, and Glowing Embers Installing Log NoOperating Stove with B-VENT Burner System For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsGhrc Series Operation Optional RemoteThermostat Control Operation Ghrcta Series OperationInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsSpecifications AccessoriesIllustrated Parts Breakdown Sbvrbn SbvrbpParts List KEY Part Number Description QTYAmity SCIVFC* Series PSCIVFC* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information

SBVRBP, SBVRBN specifications

Vanguard Heating has made significant strides in the heating industry with its innovative product line, including the SBVRBN and SBVRBP models. These heating solutions are designed for both residential and commercial applications, prioritizing efficiency, durability, and advanced technology.

The SBVRBN model stands out with its high performance output, making it ideal for areas needing rapid heating. This model utilizes state-of-the-art heating elements that ensure even warmth distribution, thereby eliminating cold spots and enhancing comfort. Additionally, its compact design allows for installation in various spaces without consuming excessive floor area.

One of the standout features of the SBVRBN model is its smart technology integration. Equipped with Wi-Fi connectivity, users can easily control the temperature remotely via a smartphone app, enabling them to preheat spaces before arriving home. This feature not only enhances convenience but also contributes to energy savings, as users can adjust heating schedules according to their lifestyle.

The SBVRBP variant focuses on energy efficiency, meeting rigorous standards that result in lower energy bills. It is equipped with advanced thermostatic controls that constantly monitor and adjust the heating output based on the ambient temperature. This technology ensures that the heating system operates only when necessary, reducing unnecessary energy consumption while maintaining comfort.

Both the SBVRBN and SBVRBP models feature durable construction with high-quality materials that are designed to withstand the test of time. Corrosion-resistant components and advanced insulation techniques contribute to longevity and consistent performance. Furthermore, their quiet operation is a significant benefit, making them suitable for environments where noise is a concern, such as offices or bedrooms.

Safety is a paramount consideration in Vanguard Heating's designs. Both models are equipped with multiple safety features, including overheating protection and automatic shut-off mechanisms. These enhancements provide peace of mind for users, knowing that their heating solutions operate safely and reliably.

In summary, Vanguard Heating’s SBVRBN and SBVRBP models represent a perfect blend of innovation, efficiency, and reliability. With smart technology, energy efficiency, durable construction, and safety features, these heating solutions are designed to meet the diverse needs of modern users, making them a compelling choice in the heating market.