Vanguard Heating SBVRBP Installation Items Needed, Tion. Purchase the CSA/AGA design-certi

Page 13

OWNER’S MANUAL

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

Installation Items Needed

Before installing stove and burner system, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas con- nector (if allowed by local codes) (not provided)

* An CSA/AGA design-certified equip-

ment shutoff valve with 1/8" NPT tap is an

acceptable alternative to test gauge connec-

tion. Purchase the CSA/AGA design-certi-

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from burner system (see Figure 29).

Check your building codes for any special requirements for locating equipment shutoff valve to stoves.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 29. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

fied equipment shutoff valve from your

dealer.

Figure 28 - External Regulator with Vent Pointing Down (Propane/LP Only)

For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 28. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter-

Approved Flexible

Gas Line

3" Minimum

CSA/AGA Design- Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Natural - From Gas

Meter (5" W.C. to 10.5"

W.C. Pressure )

LP - From External Regulator (11" W.C. to 14" W.C. Pressure)

nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to burner sys- tem. If pipe is too small, undue loss of pressure will occur.

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

*The CSA/AGA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your dealer.

Figure 29 - Gas Connection

Continued

106707

13

For more information, visit www.desatech.com

Image 13
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySbvrbn and Sbvrbp Cast Iron Stove and Burner System Safety InformationProduct Identification Product FeaturesLocal Codes OperationLocation and Space Requirements PRE-INSTALLATION PreparationStove Body Assembly Cast Iron Stove and B-VENT Burner System AssemblyAttaching Stove Legs Installing Optional Blower Accessory Installing B-VENT Burner System Into Stove BodyInstalling Rear Cover Cast Iron Stove and DIRECT-VENT Burner System AssemblyInstallation Precautions Venting InstallationType B-VENT Installation Listed B-0 or Greater Installing Vent System in a Chase Installation of Listed B-1 VentChecking Vent Capacity Chimneys High Altitude InstallationRelining Systems Cast Iron Stove and B-VENT Burner System Installation Troubleshooting Venting ProblemsTion. Purchase the CSA/AGA design-certi Installation Items NeededPressure Testing Gas Supply Piping System Connecting STOVE/ Burner System to GAS SupplyPressure Testing Burner System Gas Connections Checking GAS ConnectionsInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Thermostat Base Terminal W and R Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing 9-Volt Battery in Hand- Held Remote Control UnitInstalling Log No Installing LOGS, Lava ROCK, and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Stove with B-VENT Burner System Lighting InstructionsThermostat Control Operation Optional RemoteGhrc Series Operation Ghrcta Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsAccessories SpecificationsSbvrbn Sbvrbp Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVFC* Series PSCIVFC* SeriesKEY Part Description QTY Warranty Information

SBVRBP, SBVRBN specifications

Vanguard Heating has made significant strides in the heating industry with its innovative product line, including the SBVRBN and SBVRBP models. These heating solutions are designed for both residential and commercial applications, prioritizing efficiency, durability, and advanced technology.

The SBVRBN model stands out with its high performance output, making it ideal for areas needing rapid heating. This model utilizes state-of-the-art heating elements that ensure even warmth distribution, thereby eliminating cold spots and enhancing comfort. Additionally, its compact design allows for installation in various spaces without consuming excessive floor area.

One of the standout features of the SBVRBN model is its smart technology integration. Equipped with Wi-Fi connectivity, users can easily control the temperature remotely via a smartphone app, enabling them to preheat spaces before arriving home. This feature not only enhances convenience but also contributes to energy savings, as users can adjust heating schedules according to their lifestyle.

The SBVRBP variant focuses on energy efficiency, meeting rigorous standards that result in lower energy bills. It is equipped with advanced thermostatic controls that constantly monitor and adjust the heating output based on the ambient temperature. This technology ensures that the heating system operates only when necessary, reducing unnecessary energy consumption while maintaining comfort.

Both the SBVRBN and SBVRBP models feature durable construction with high-quality materials that are designed to withstand the test of time. Corrosion-resistant components and advanced insulation techniques contribute to longevity and consistent performance. Furthermore, their quiet operation is a significant benefit, making them suitable for environments where noise is a concern, such as offices or bedrooms.

Safety is a paramount consideration in Vanguard Heating's designs. Both models are equipped with multiple safety features, including overheating protection and automatic shut-off mechanisms. These enhancements provide peace of mind for users, knowing that their heating solutions operate safely and reliably.

In summary, Vanguard Heating’s SBVRBN and SBVRBP models represent a perfect blend of innovation, efficiency, and reliability. With smart technology, energy efficiency, durable construction, and safety features, these heating solutions are designed to meet the diverse needs of modern users, making them a compelling choice in the heating market.