Vanguard Heating SBVRBN, SBVRBP PRE-INSTALLATION Preparation, Location and Space Requirements

Page 4

® SBVRBN AND SBVRBP

CAST IRON STOVE AND BURNER SYSTEM

PRE-INSTALLATION PREPARATION

WARNING: A qualified in- staller or service person must install stove and burner system. Follow all local codes.

CAUTION: This stove with burner system creates warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove with burner system where impurities (such as tobacco smoke, aromatic candles, clean- ing fluids, oil or kerosene lamps,

On Wall with Vertical

Corner Installation

Termination Through

with Vertical

Ceiling

Termination

 

Through Ceiling

Figure 2 - Common Stove Locations

Ceiling

etc.) in the air exist, may discolor walls.

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient loca- tion for your Vanguard B-vent cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows, or doors. Figure 2 shows some common locations. Read all venting infor- mation in this manual. Be aware of all restric- tions and precautions before deciding the

42"

36"

from

Front

4"

from

Back 21 1/4" Wall

4"

6"

Front

exact location for your stove.

Floor

29"

When deciding the location of your stove, follow these rules:

Figure 3 - Clearances for Standard Installation

1.

Do not connect this stove and burner

 

sytem to a chimney flue serving a

 

separate solid-fuel burning fireplace or

 

appliance.

2.

Due to high temperatures, do not lo-

 

cate this stove in high traffic areas or

 

near furniture or draperies.

3.

Proper clearances must be maintained,

 

see Figures 3 and 4.

4.

This stove is a freestanding unit de-

 

signed to set directly on the floor. If

 

your stove is to be installed directly on

 

carpeting, vinyl tile, or any combustible

 

material other than wood, it must be

 

installed on a metal or wood panel ex-

 

tending the full width and depth of the

4" 4"

26 1/4"

Front

19 1/2"

stove. See Figure 5.

Figure 4 - Clearance for Corner Installation Figure 5 - Stove With Burner System Bottom Dimensions

For more information, visit www.desatech.com

4

106707

Image 4 Contents
For Your Safety For Your Safety What to do if YOU Smell GASSafety Information Sbvrbn and Sbvrbp Cast Iron Stove and Burner SystemProduct Features Product IdentificationLocal Codes OperationPRE-INSTALLATION Preparation Location and Space RequirementsCast Iron Stove and B-VENT Burner System Assembly Stove Body AssemblyAttaching Stove Legs Installing B-VENT Burner System Into Stove Body Installing Optional Blower AccessoryCast Iron Stove and DIRECT-VENT Burner System Assembly Installing Rear CoverInstallation Precautions Venting InstallationType B-VENT Installation Listed B-0 or Greater Installing Vent System in a Chase Installation of Listed B-1 VentChecking Vent Capacity Chimneys High Altitude InstallationRelining Systems Troubleshooting Venting Problems Cast Iron Stove and B-VENT Burner System InstallationInstallation Items Needed Tion. Purchase the CSA/AGA design-certiConnecting STOVE/ Burner System to GAS Supply Pressure Testing Gas Supply Piping SystemPressure Testing Burner System Gas Connections Checking GAS ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Installing Remote Receiver Thermostat Base Terminal W and RInstalling 9-Volt Battery in Hand- Held Remote Control Unit REMOVING/REPLACING Glass DoorInstalling LOGS, Lava ROCK, and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Stove with B-VENT Burner System Lighting InstructionsOptional Remote Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Technical ServiceWiring Diagram Service HintsSpecifications AccessoriesIllustrated Parts Breakdown Sbvrbn SbvrbpParts List KEY Part Number Description QTYAmity SCIVFC* Series PSCIVFC* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information