Turbo Chef Technologies NGC-1007 Removing and Installing the Catalytic Converter, 119, 122

Page 65

52 IR ELEMENT AND CATALYTIC CONVERTER

Removing and Installing the Catalytic Converter

1.Unplug the oven.

2.Remove the IR element. (See above procedure.)

3.Once the IR element has been removed, remove the catalytic converter clip (Item 121) to access the catalytic converter. Figure 39.

N O T E : It may be necessary to remove the blower motor assembly (see page 48) to get access to the top of the catalytic converter. This will allow the catalytic converter to be pushed down out of the housing. Figure 39.

4.Remove the catalytic converter (Item 122).

5.Inspect the condition of the catalytic converter and either clean it or install a new one.

C A U T I O N : Clean catalytic converter using only TurboChef cleaner (P/N 103180 USA, 103380 Intl). Use of other chemicals will irreparably damage catalyst.

Installing a New IR Element

1.Unplug the oven.

2.Gently squeeze the new IR element together in order to get the terminals and lead wires into the cavity and through the mounting holes.

119

 

118

122

 

119

x4

120

C A U T I O N : Do not allow the thermocouple lead wires to kink. They are solid wire and will break.

3.Once the IR element is installed, expand the IR element in order to reinstall the shim washers (Item 117) and snap rings (Item 116). Figure 39.

N O T E : Be sure that the snap rings sit in the grooves on IR element.

4.Reconnect the IR element lead wires to the EMI filter and the high-limit thermostat.

5.Reconnect the IR thermocouple lead wires

to the thermocouple extension wires – Yellow to Yellow and Red to Red.

IR ELEMENT AND CATALYTIC CONVERTER PARTS

Figure 39

 

116. 101312

Snap Ring

117.102449 Washer, Shim

118.NGC-3003 IR Element

119.NGC-1116 Shield, Microwave

120.101688 Screw, #8 x 1/2” Sht Metal PTH

121.NGC-1030 Clip, Catalytic Converter

(Non-SBK)

NGC-1233 Clip, Catalytic Converter (SBK)

122. NGC-1012 Catalytic Converter

116

122 117

118121

F I G U R E 39: IR Element and Catalytic Converter Assembly

Image 65
Contents Accelerating the World of Cooking For further information call Important Safety Information Please Read First Table of Contents Oven Door Microwave SystemService Parts and Illustrations Schematics and Schematic ComponentsConvection Circuit IR Element and Catalytic ConverterImportant Safety Instructions Grounding Instructions Installation, Specifications, and Maintenance Standard Features DimensionsPower Supply North America ConstructionPower Supply Latin America Power Supply Europe, Asia-PacificPower Supply South Korea Built-In Installation FigureInstallation Near Open Heat Source Figure Initial Power-up SetupOven Restraint Kit TC3-0242 KIT StackingRemove and Clean the Cooking Surface Remove the Lower Access PanelClean Oven Interior Clean Lower Access Panel AreaTheory of Operation Chapter Set Temperature, IR Element Irsp and Irsi Set Temperature, Cook Cavity CcspActual Temperature, Cook Cavity TCC Actual Temperature, IR Element TIRKeypad Fault CodeDisplay Self-Test StestFault Codes F1 Blower Running Status Bad F2 Cook Temperature LowF3 Magnetron Current Low F4 Door Monitor DefectiveThermocouple temperature is below the indicated limit F5 Magnetron Over TemperatureF7 Thermocouple Open F8 Heat LowControl System Mech Interlock Switches VDC Power SupplyK1 Mechanical Relay K2 Mechanical RelayBlower Speed Screen Faults ScreenSelf-Test Function Screen Heater Test ScreenElectronic Compartment Temperature Screen Diagnostic Display ScreenChanging the Cook Chamber Temperature Cooks ScreenAltering a Recipe Loading a Menu from a Smart Card Snooze ModeDone Screen Time ScreenEnter Key Code Function/ScreenSmart Card Reader Cable Board J3 connector Replace I/O control board Reference page 54 for a schematic of the I/O control boardPin connector If not, correct the voltage supplyTroubleshooting VAC is going to the motor controller via pins 2Refer to page 50 for motor controller troubleshooting Detailed troubleshootingIf high-limit is not tripped, follow the instructions below Microwave System Voltage Doubler Circuit Description Microwave System Filament and High Voltage Terminals ORG High-Voltage Transformers MagnetronFilament Transformers F3 FuseWave Guide Cover Replacement NGC-3036Kit, Wave Guide Cover Includes Item 31 and sealant Wiring the High-Voltage TransformersScrews, #8, SST NGC-1047Support, Frame Remove the wave guide cover. See Wave GuideProcedure for Measuring RF Leakage Wiring the Filament TransformersHow to Check a Diode Testing the High-Voltage DiodeHow to Check a High-Voltage or Filament Transformer How to Check a CapacitorComponents MagnetronRemove the top and right side covers Back and Enter keys, enter the code 9-4-2-8 and press EnterVoltage Transformers HV capacitor shorted or failing follow troubleshooting onMgtron soft key. Voltage present should be 200 +/- 10% Unplug the oven and replace relay if necessaryPrimary and secondary, the control would have recorded Troubleshooting see F4 MonitorOccurrence. See page 25 as well as Oven Door for Energizing the Microwave SystemOven Door Oven Door Oven Burn-In Procedure Critical Adjustment Notes31 for proper procedure Primary and Secondary Interlock Switch Adjustments and Parts PPHD, Cres Assembly Notes5963 Adjusting the Primary Interlock Switch NEW Switch Setup DIA 80 8198 AR 101Refer to Figures 35 Critical Adjustment Notes FigureActuator and toggle OK Check adjustment and wiring on Interlock switch statusNew setup for the proper adjustment procedure Door does not close freely Remove obstructions or readjustConvection Circuit Motor Controller Bmsc Main Convection HeaterHigh Limit Thermostat Convection Motor114 105 104 103 102 107 109 110 113 111108 106† Thermostat tripped Reset and determine why the thermostat Replace motor. For access to motor shaft, remove top panelCook Door Open Message Verify which switch is not actuating Readjust. See pages † Motor spins freely Verify motor windings see table below Verify motor spins freely Disconnect control wiring Plug on schematics pages 55-63 while incrementing blowerConverter Removing the IR Element IR ElementCatalytic Converter Installing a New IR Element Removing and Installing the Catalytic Converter119 122Schematics and Schematic Components Low Voltage Components Wire Harness Replacement P/NsLine Voltage Components Board Schematic Schematic Tornado NGC MAG Schematic Tornado Ngcew Schematic Tornado Ngced Schematic Brazil NGC Service Parts and Illustrations Relay Control SystemService Parts and Illustrations Monitor Circuit Shown in Failsafe State Microwave SystemWave Guide/Wave Guide Cover Parts Microwave System PartsSBK Oven DoorDoor Switch Parts Primary and Secondary Interlock Switch PartsPrimary Safety Switch Parts Monitor Safety Switch Parts80 81 Secondary and Monitor Safety Switch Parts Oven Door Parts 100Convection Circuit Convection Circuit Block Diagram114 105 104 103 102 107 108 106 109 110 113 111 112 Convection Circuit Parts123 Old Switch Setup 126 Wire Harness Replacement P/NIR Element and Catalytic Converter 122 119135 137 138 133 134 129 132 144 139 141150 Screw, #8-32 x 3/8, Pphd NGC-2011-8 147 150 162 157 159153 155 156 151 152 Comprehensive Part List Comprehensive Part List Comprehensive Part List Relay, K7, Magnetron Fan, Standard Europe, Asia-Pacific MPh Smart Card, Programmed call TurboChef for Part Numbers 800.90T U R B O or