Kenmore 625.385700, 625.385720 owner manual Install Storage TANK, Make Remaining Tubing Connections

Page 10

-STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS -

1. CONNECT DRAIN TUBING, FAUCET TO

DRAIN ADAPTER: Referring to Figure 10, run the loose section of black 3/8" tubing from the faucet to

the drain adapter, with a black collet, installed on

page 6. Cut this tubing as needed to route in as

straight of a run as possible, without loops, dips, low spots or kinks. Cut the end of the tubing square. Then push all the way into the fitting. Pull on the tub- ing to be sure it's held firmly in the adapter fitting.

See page 16 for tubing connection instructions.

2. CONNECT TUBING TO WATER SUPPLY: Con- nect the feed (green) tube to the water supply fitting

installed on page 5. Connection to the fitting is as

RO product water faucet

UltraFilter 350 2_

water supply

fitting

drain

 

 

adapter

 

HOT COLD

 

sink p-trap

tubing adaptor

yellow collet

described in Figure 14, page 16.

3.Move the storage tank into place next to the RO as-

sembly. You can stand the tank upright, or lay it on side. Apply no more than two wraps of Teflon tape

to the threads on the nipple at the top of the tank.

Hand tighten the other included tubing adapter fit-

ting with the yellow collet onto the tank nipple, then

wrench 1/4 turn only. BE CAREFUL NOT TO CROSS THREAD.

4.Run the 3/8" yellow tubing to the fitting installed in step 3. Be sure the end of the tubing is cut square, and insert all the way into the fitting. Again, pull on the tubing to be sure it's held firmly in the fitting.

TYPICAL UNDERSINK INSTALLATION

RO product water faucet

UltraFilter 150

3/8" BLACK TUBING

Note: See note on page 4

regarding tubing lengths.

Figure 10

10

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Image 10
Contents Model no UltraFilter 150 UltraFilter 350Full Warranty on Reverse Osmosis Drinking Water System WarrantySafety Guides Except filter Cartridges and R. O. membraneBefore YOU Begin to Install the RO System Table of ContentsWhat Your Reverse Osmosis System will do Steps to Install Where to Install the RO SystemTools and Materials Needed Codes as Install Cold Water Supply FittingCheck Comply Water Supply Fitting Optional Pipe FittingsInstall Faucet Install Drain AdapterPrepare Mounting Hole Assemble Faucet Ultrafilter Install FaucetUltraFilter Assemble Faucet InstallFaucet Tubing RO SystemInstall RO Assembly Faucet ElectronicsTypical Undersink Installation Install Storage TANK, Make Remaining Tubing ConnectionsConnect Drain TUBING, Faucet to Pressure Testing SANITIZING, Pressure Testing & PurgingSanitizing Faucet HOW Your Reverse Osmosis System WorksFlow Control Itl Care of Your Reverse Osmosis System Prefilter and Post Filter CartridgesRO Membrane Cartridge USE Soap Anwater Automatic Shutoff ServiceChanging Collet and O-ring Figure Other Troubleshooting CorrectionDimensions and Specifications MetricRemote RO Installation Remote Installation LocationsStorage tank not shown Repair Parts 19i 812Key Part Description of Part Number KeyProblems, Questions? Call 1-800-426-9345 Kenmore Water Line Problems, Questions? Call 1-800-426-9345 Kenmore Water Line Your Home Matter who made it, no matter who sold it