- DIMENSIONS and SPECIFICATIONS -
13"
11"
|
|
|
|
|
|
|
|
|
|
|
|
|
| Metric | |
Supply | water | pressure | limits | 40 | - | 100 | psi | 280 | - | 690 kPa | |||||
Supply | water | temperature | limits | 40 | - | 100 | °F | 5 | - | 40°C | |||||
Maximum total dissolved solids (TDS) | 2000 ppm |
|
|
| |||||||||||
Maximum | water | hardness | @ 6.9 pH |
| 10 gpg |
|
|
|
| ||||||
Maximum | iron, | manganese, hydrogen sulfide |
|
| 0 |
|
|
|
| ||||||
Chlorine |
| in water supply |
| (max. ppm) |
|
| 2.0 |
|
|
|
| ||||
Supply | water | pH limits | (pH) |
| 4 | - | 10 |
|
|
|
| ||||
Product | (quality) water, | 24 hours | ................. |
| 14 gal. |
| 53 liters | ||||||||
Waste water | per gallon | of product | water |
| 5 gal. |
| 18.9 liters | ||||||||
Percent | rejection of TDS, | minimum | (new membrane) _ |
| 90 - | 95 |
|
|
| ||||||
Storage | tank | capacity (max.) |
| 2.3 | gal. |
| 8.7 | liters | |||||||
Automatic | shutoff control | ........................... |
|
| yes |
|
|
|
| ||||||
Efficiency | 12 | ...................................... |
|
|
|
|
| 8 % |
|
|
|
| |||
Recovery | 13 |
|
|
|
|
| 16 % |
|
|
|
|
This system conforms to NSF/ANSI 58 for the specific performance claims as verified and sub- stantiated by test data.
Feed water supply at 50 psi, 77°F, and 750 TDS - Quality water production, amount of waste water and percent rejection all vary with changes in pressure, temperature and total dissolved solids.
12 Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage.
13 Recovery rating means the percentage of the inftuent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
18
Problems, Questions? Call