- CARE OF YOUR REVERSE OSMOSIS SYSTEM -
REVERSE OSMOSIS SYSTEM CARE GUIDE
MODEL NOs. 625.385700 & 625.385720
1.AT LEAST every 6 months, replace the prefilter and postfilter cartridges or when red LED flashes,
2.Replace the RO membrane cartridge when the percent rejection of total dissolved solids (TDS) is less than shown in the specifications (see B, below).
3.Replace the battery once per year.
If any of the following occur before the 6 months, replace as directed.
A. Slow Making of Product Water: Replace the prefilter cartridge. tf the production rate does not improve, replace the post filter car- tridge and RO membrane cartridge.
B. High Total Dissolved Solids (TDS) in Product Water: You can get a free TDS test through some Sears retail stores or service departments, tf the store or service department does not have a TDS meter, you can send treated and untreated water samples to a water analysis lab for testing. It is important to test both the treated and untreated water to determine system performance. If the TDS is not within the system's performance guidelines, replace the prefilter, post filter and RO membrane cartridges.
C. Chlorine Taste and/or Odor: Replace the prefilter, post filter and RO membrane cartridges.
OTHER TROUBLESHOOTING
PROBLEM | CAUSE | CORRECTION |
Chlorine | taste | and/or | The ppm | of chlorine | in your | water supply |
odor in the RO product | exceeds | maximum | limits, | and has de- | ||
water |
|
| stroyed the RO membrane. |
| ||
|
|
| The prefilter is no longer removing chlo- | |||
|
|
| rine from the water supply. |
| ||
Other taste and/or odor | Post filter | expended. |
|
| ||
|
|
| RO membrane cartridge expended. | |||
|
|
| Contamination in product water storage. | |||
System | makes | product | Water supply to the RO system not within | |||
water too slowly |
| specifications. |
|
| ||
|
|
| Prefilter or RO membrane cartridges | |||
|
|
| plugged | with sediments. |
|
System makes lower Storage tank
amount of product water psi. than usual
High total dissolved sol- Water supply to the RO system not within ids (TDS) in product wa- specifications,
ter | RO membrane cartridge expended. |
Water leaking from fau- Drain side of faucet airgap (3/8" tubing)
cet airgap holeplugged, restricted, or incorrectly con- nected to drain point.
tf the water supply contains more than 2.0 ppm of chlorine, addi- tional filtering of the water supply to the RO is needed. Correct this condition before doing maintenance on the RO system.
Replace the prefilter, post filter and RO membrane cartridges.
Replace the post filter cartridge. If taste and odor persists, re- place the prefilter cartridge and RO membrane cartridge.
Use sanitizing procedures. Replace the post filter cartridge.
Increase water pressure, precondition the water, etc., as needed to conform before doing maintenance on the RO system.
Replace the prefilter cartridge. If rate does not increase, replace the postfilter cartridge and RO membrane cartridge.
Open RO faucet and drain tank until flow slows to a drip. Keep
faucet open and check tank pressure. If low, pressurize to 6 psi. Close faucet to refill the tank.
Increase water pressure, precondition the water, etc., as needed to conform before doing maintenance on the RO system,
Replace the prefilter, postfilter and RO membrane cartridges, flow control, and screen.
Inspect and eliminate restriction or plug. Refer to installation instructions for proper drain connection.
Continual | water | flow to | Check valve | or automatic shutoff assem- | Clean, repair or replace as needed. | |||
drain |
|
| bly plugged, | restricted or parts worn |
|
| ||
Faucet | LED | indicator | Batteries | dead. |
| Replace | with new batteries. | |
light does not function af- |
|
|
|
|
|
| ||
ter battery change | Batteries | installed | incorrectly. | Install batteries correctly. | ||||
Continual | water | flow to | Missing flow restrictor in red drain tube or | Replace | flow restrictor. | |||
drain and no product wa- | its corresponding | port. |
|
| ||||
ter |
|
|
|
|
|
|
|
|
Faucet | LED | indicator | Filters needreplacing. | Change | filters. |
light flashing red
Note: Sanitizing is recommended after servicing inner parts of the system(see page 11).